TG0047A

Section A: Wiring Diagrams

Figure 3 — N1388-1 Alternator with N3012 Regulator

Figure 2 — N1388-1 Alternator Terminals

(N3012 Regulator Attached to Alternator)

B+ terminal

T

Diagnostic

receptacle

CEN N1388-1 Alternator

Description and Operation

N1388-1 28 V (300 A) alternator is self-rectifying.

All windings and current-transmitting components
are non-moving, so there are no brushes or slip rings
to wear out. Load-dump protection limits peak voltage
to less than 55 volts during maximum load change
over speed range in batteryless operation. Peak ampli-
tude of voltage including ripple during normal battery-
less operation is less than 40 volts. Radio noise sup-
pression is in accordance with Mil-Std 461A, Notice 4
RE05 and CE07.
Ignition switch energizes regulator, and then field coil
is energized. Voltage adjustment is available on alter-
nator control unit.
N3012 regulator furnished with this unit is flat tem-
perature compensated at 28.1±0.15 V at 72 F.

B– terminal

T

T

T

T

Regulator

receptacle

T

Energize

receptacle

T

Voltage

adjust plug

receptacle

Figure 1 — N1388-1 Control Assembly