C.E. Niehoff & Co. C715/C716 Troubleshooting Guides User Manual
Page 6
Page 6
TG0007A
C. E. Niehoff & Co.
BRUSHLESS ALTERNATORS
Section 3: Advanced Troubleshooting
(CONTD)
Chart 3 – No Alternator Output – Ignition Switch
Ignition Switch
Ignition Switch
Ignition Switch
Ignition Switch – Test Charging Circuit
Jumper B+ terminal on alternator to E terminal
on regulator. Touch shaft with steel tool to detect
significant magnetism. Is shaft magnetized?
Yes
No
G
G
Disconnect jumper. Apply 12 V test light to
regulator E terminal and ground. Does light
glow brightly?
Yes
No
Run vehicle. Does charge voltage exist?
System
operating
normally.
Repair wiring or
ignition switch.
Yes
No
G
Jumper B+ terminal on
alternator to regulator
E terminal. Does charge
voltage exist?
Yes
No
G
Repair wiring
or ignition
switch.
G
Contact CEN
Service
Department
for assistance.
G
G
G
Test for battery voltage at B+ terminal on alternator to ground, then at F+ terminal on regula-
tor to ground. Does battery voltage exist?
Yes
No
Repair vehicle wiring as necessary. Continue test.
STATIC TEST ENGINE OFF, BATTERY SWITCH ON, KEY ON
Figure 4 Alternator-to-Regulator Harness Plug
G
G
G
SOCKET CONNECTIONS
Socket A B
Socket B Field +
Socket C Field
Socket D Phase (R)
Socket E B+
G
Yes
Unplug alternator-to-regulator harness. Plug CEN
Regulator Bypass Adapter A10-129 into harness
plug. Make sure black lead does not touch
ground. Clip red lead to B+ terminal on alternator.
(If Adapter is not available, connect jumper wire
from socket B on harness to alternator B+ termi-
nal.) Does spark occur at alternator B+ terminal?
Disconnect Regulator Bypass Adapter or jumper
wire. Connect DMM red lead to socket E in alter-
nator-to-regulator plug. Connect black lead to
socket A in same plug. Does battery voltage exist?
Regulator is defective.
Yes
No
Disconnect Adapter or jumper
wire. Alternator is defective.
No
Alternator is defective.
G
G
Touch black lead to ground on alternator case.
(If Adapter is not available, connect jumper wire
from socket C on harness to ground.) Spark will
occur at ground. Touch steel tool to shaft to
detect significant magnetism. Is shaft magne-
tized?
Yes
No
Disconnect Adapter or jumper
wire. Alternator is defective.
G
G
G
G