beautypg.com

C.E. Niehoff & Co. N1617 Alternator/N3264 Regulator Installation User Manual

Page 2

background image

If you have questions about your alternator or any of these instructions, or if you need to locate a Factory Authorized Service Dealer, please contact us at:

C. E. Niehoff & Co.• 2021 Lee Street • Evanston, IL 60202 USA

TEL: 800.643.4633 USA and Canada • TEL: 847.866.6030 outside USA and Canada • FAX: 847.492.1242

E-mail us at [email protected]

II141A

Page 2 of 2

B– connections on alternator
Bolt, 0.3750-16 UNC-2A x 0.875; torque to 20 Nm / 15 lb.ft. when securing B– cables.

Both ground cables must be connected to vehicle’s common ground.

An interconnect cable is required as shown if a single cable to vehicle common ground is used.

Lock Washer

Interconnect cable

Figure 2 - Alternator B– Installation Details

B+ connections on alternator — see Page 1 for complete wiring

Washer

Ground cable from vehicle