C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633

II154E

Page 4 of 4

Figure 3 – Wiring Diagram

Figure 4 – Connections and Torque Values for Reference Only

Terminal A (wht)
Terminal B (wht w/blk)
Terminal C (wht w/red)

PHASE WIRE
CONNECTIONS:

Terminal F:

B–

Terminal D:

B+

Output cable
SEE STEP 1, PAGE 1

FIELD COIL
CONNECTION:
F– (wht)

FIELD COIL
CONNECTION:
D+
(wht w/ yellow: C192)
(wht w/red: C193)

All connections shown

(except where noted)

should be torqued to

2.9-3.9 Nm/26-35 lb. in.

Internal Earthing Bonding
M6 x 1 x 8mm screw
w/sems lockwasher
Torque to 14.9 Nm/132 lb. in.
SEE TABLE 1 and STEP 3

External Earthing Bonding
M6 x 1 x 10mm screw
w/sems lockwasher
Torque to 14.9 Nm/132 lb. in.
SEE TABLE 1, PAGE 1

Phase wire