beautypg.com

C.E. Niehoff & Co. 200 & 300: Regulator Upgrade Installation User Manual

Page 2

background image

II0002C

Page 2 of 2

C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633

200 Series – A1-200, A1-201, A1-202

N1025, N1026, N1031, N1036, N1037, N1077, N1079,

N1080, N1085, N3036, N7024, N7031, N7040

1. Remove end housing assembly, voltage adjust-

ment cover, screw, and voltage adjustor insula-
tor.

2. Using the third hole as the pilot hole, drill a

9/16” hole.

3. Deburr new hole to prevent damaging new

switch on new circuit board.

4. Install new circuit board and wire per

Figure 4.

Figure 3 - Series 200 Cover Assembly

“R” Lead

(brown wire)

Figure 4 - Series 200 Wiring

“Y” Lead

(brown wire)

Field Lead

(white wire)

Output Lead

(red wire)

GROUND

(white wire)

Voltage Select Switch Position

A2-434 Reg. A2-435 Reg.

Position 1—13.8 V

Position 1—27.6 V

Position 2—14.2 V

Position 2—28.0 V

Position 3—14.6 V

Position 3—28.5 V

Position 4—14.6 V

Position 4—29.0 V