Form 1145 Mini Installation Form and Operation Manual 02/02/2006

7

G e t t i n g S p e e d

G e t t i n g A c c e l

At this point a servo feed ready for normal operation.

Units of measure are displayed in inches or meters/millimeters, depending on the value of the scale parameter.
Standard Scale values are: 4106.7 counts/inch and 161.7 counts/mm.

1

L e n g t h : 2 . 5 4 i n

2

S p e e d :

1 0 0 i n / s

3

A c c e l : 4 0 0 i n / s

^ 2

E

n t e r c h o i c e :

1

L e n g t h : 2 5 . 4 m m

2

S p e e d :

2 . 5 m / s

3

A c c e l : 1 0 m / s

^ 2

E

n t e r c h o i c e :

To Change:

>

Length press ‘1’ then ‘ENTER’

>

Speed press ‘2’ then ‘ENTER’

>

Accel press ‘3’ then ‘ENTER’

4.1

ENTER FEED LENGTH

Enter in ‘1’ and press ‘ENTER’.

1

L e n g t h : 2 . 5 4 i n

2

S p e e d :

1 0 0 i n / s

3

A c c e l : 4 0 0 i n / s ^ 2

E

n t e r c h o i c e :

Enter in the new feed Length and press ‘ENTER’ or to cancel, press ‘ENTER’ (leave the Length field blank).

L

e n g t h : 2 . 5 4 i n

N

e w L e n g t h :

P

r e s s E N T E R t o e x i t

L

e n g t h : 2 . 5 4 i n

N

e w L e n g t h : 3 . 0 0

P

r e s S E N T E R t o e x i t