PA Industries MINI Servo Roll Feed SRF-105M through SRF-320 User Manual
Page 7

Form 1145 Mini Installation Form and Operation Manual 02/02/2006
7
G e t t i n g S p e e d
G e t t i n g A c c e l
At this point a servo feed ready for normal operation.
Units of measure are displayed in inches or meters/millimeters, depending on the value of the scale parameter.
Standard Scale values are: 4106.7 counts/inch and 161.7 counts/mm.
1
L e n g t h : 2 . 5 4 i n
2
S p e e d :
1 0 0 i n / s
3
A c c e l : 4 0 0 i n / s
^ 2
E
n t e r c h o i c e :
1
L e n g t h : 2 5 . 4 m m
2
S p e e d :
2 . 5 m / s
3
A c c e l : 1 0 m / s
^ 2
E
n t e r c h o i c e :
To Change:
>
Length press ‘1’ then ‘ENTER’
>
Speed press ‘2’ then ‘ENTER’
>
Accel press ‘3’ then ‘ENTER’
4.1
ENTER FEED LENGTH
Enter in ‘1’ and press ‘ENTER’.
1
L e n g t h : 2 . 5 4 i n
2
S p e e d :
1 0 0 i n / s
3
A c c e l : 4 0 0 i n / s ^ 2
E
n t e r c h o i c e :
Enter in the new feed Length and press ‘ENTER’ or to cancel, press ‘ENTER’ (leave the Length field blank).
L
e n g t h : 2 . 5 4 i n
N
e w L e n g t h :
P
r e s s E N T E R t o e x i t
L
e n g t h : 2 . 5 4 i n
N
e w L e n g t h : 3 . 0 0
P
r e s S E N T E R t o e x i t