Excessive Output 
Frequency 
ON indicates the motor 
encoder output frequency 
exceeds the maximum 
value. 
 
 
Note: This fault can only be 
generated when the 
encoder output is 
synthesized by the 
Ultra3000. 
 
Encoder output frequency 
exceeds the maximum value. 
Increase the encoder output 
maximum frequency 
parameter. 
 
Decrease the encoder 
interpolation parameter. 
 
Increase the encoder output 
divider parameter. 
 
Reduce motor speed. 
 
30
Encoder Communication 
 
ON indicates loss of 
communication with an 
intelligent encoder. 
 
Communication was not 
established with an intelligent 
encoder. 
Verify motor selection. 
 
Verify the motor supports 
automatic identification. 
 
Verify motor encoder wiring. 
 
31
Encoder Data 
 
ON indicates encoder data 
is corrupted. 
 
Encoder data is corrupted. 
 
Replace the motor/encoder. 
 
32
Excessive Interpolated 
Feedback Frequency 
ON indicates Sine/Cosine 
frequency of encoder 
exceeds specified value. 
Note: This fault can only be 
generated when the 
encoder output is 
synthesized by the 
Ultra3000. 
 
Encoder output frequency 
exceeds the maximum user 
specified value. 
 
Reduce motor speed. 
Use encoder with lower 
resolution (before 
interpolation). 
 
33
Absolute Position 
Exceeds Position 
Rollover 
ON indicates motion is 
commanded to a position 
outside the position rollover 
range. The position rollover 
range is [0 .. machine cycle 
size - 1]. 
Note: This fault can only be 
generated when the 
machine cycle position 
rollover is enabled. 
 
An absolute index is initiated 
that specifies a position 
outside the position rollover 
range. 
A homing cycle is initiated with 
the home position outside the 
position rollover range. 
A define home is initiated with 
the home position outside the 
position rollover range. 
A preset position is initiated 
that specifies a position 
outside the position rollover 
range. 
The home position parameter 
is changed to a value outside 
the position rollover range, the 
system has absolute feedback 
and the drive is reset or power 
cycled. 
 
Set motion command to a 
position within the position 
rollover range. 
 
34
Ground Short Circuit 
 
ON indicates the motor 
ground is shorted. 
 
Wiring error 
 
Motor internal ground short 
 
Check motor power wiring. 
 
Replace motor. 
 