23
SECTION 7: Troubleshooting (continued)
TROUBLESHOOTING GUIDE
Symptom
Cause
Solution
OIL LEAKS AT:
Seals
Worn or damaged seal
Replace seal; polish shaft
and/or shaft surface
Shims
Damaged shim
Replace; apply “Loctite Aviation
Grade Sealant” to both sides
Cap Screws
Shim damaged between screw
Replace gasket or shim; apply
hole and interior of housing
“Loctite Aviation Grade
Sealant” to both sides
Holes drilled through
Remove screw, apply
“Loctite Threadlocker” and
re-install
Cover joints
Inadequate sealant
Remove, clean and
reassemble with silicone
rubber sealant
Oil service pipe fittings
Not properly sealed
Remove, clean and reinstall
with “Loctite Teflon Pipe
Sealant”
NOTE: In the event that damage is found, it is recommended that the unit be returned to the
factory for repair or that an Industrial Motion Control Serviceman make or supervise repairs in
your plant. Proper alignment and adjustment of the components are essential to their
performance and life.