Symptom

Cause

Solution

OIL LEAKS AT:

Seals

Worn or damaged seal

Replace seal; polish shaft

and/or shaft surface

Shims

Damaged shim

Replace; apply “Loctite Aviation

Grade Sealant” to both sides

Cap Screws

Shim damaged between screw

Replace gasket or shim; apply

hole and interior of housing

“Loctite Aviation Grade

Sealant” to both sides

Holes drilled through

Remove screw, apply

“Loctite Threadlocker” and

re-install

Cover joints

Inadequate sealant

Remove, clean and

reassemble with silicone

rubber sealant

Oil service pipe fittings

Not properly sealed

Remove, clean and reinstall

with “Loctite Teflon Pipe

Sealant”