DE-STA-CO S/SM300A User Manual
Page 12
10
SECTION 4: Installation
These units are manufactured to meet a specific set of design parameters. Any change to the load on
the output shaft, or speed of the camshaft may require a size change. No change can be made without
affecting other performance characteristics of the unit and, therefore, should not be done without
consulting the factory.
4.1.
To install the unit:
4.1.1. Rotate camshaft so cam is in center of dwell (see figure 4).
4.1.2. Mount the Indexer into position on a rigid base and secure with the proper size
fastener.
4.1.3. Align the Indexer with respect to the station positions before tightening fasteners.
Use a dial indicator or other appropriate tools to insure alignment.
4.1.4. Tighten all mounting bolts securely and uniformly.
FIGURE 4