Actuator mounting codes for s92/93 - imperial (in), Actuator mounting codes for s92/93 - metric (mm), Pneumatic actuator & accessories – Bray Pneumatic Actuators & Accessories User Manual
Page 3

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customer’s detailed knowledge and experience with their application.
Pneumatic Actuator & Accessories
Installation : 3
All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customer’s detailed knowledge and experience with their application.
Pneumatic Actuator & Accessories
Installation : 3
Actuator Installation Notes
These notes apply to the installation of Bray S92/93 pneumatic valve actuators.
• Verify that the valve and the actuator are both in the same position (both open or both closed) before mounting
the actuator to the valve.
• Apply a light coating of grease to the inside of the actuator output bore before installing the actuator on the valve.
This will allow the actuator to be more easily removed from the valve stem even after years of service.
• If stem adapters are required to match the actuator output bore to the valve stem, apply a light coating of grease
to the inside of the stem adapter as well as the inside of the actuator output bore.
• Some stem adapters are kits consisting of multiple components. These kits may contain spacers that look like
stem adapters, but are designed to keep the stem adapter in place during operation of the actuator. Verify that
all stem adapters and spacers are installed in the proper position and sequence.
• If keyed stem adapters are used, the key must be held in the keyway so that it will not work loose during
operation of the actuator. The key may be retained by any one of several methods:
If the valve stem height matches the depth of the actuator output bore, use a key that fits the full length of the
keyway. Tack weld the key to the adapter before installation in the actuator.
Upset the end of the keyway after the key has been installed in the shaft by using a punch or chisel.
• If mounting studs are used instead of bolts, thread the studs completely into the actuator before placing the
actuator on the valve. This assures that the full strength of the connection is achieved.
• While the mounting bolts are only finger tight, cycle the actuator fully open and fully closed to verify proper
alignment on the valve.
• Tighten the mounting bolts or nuts in a diagonal pattern to evenly distribute stress in the bolts.
Actuator Mounting Codes for S92/93 - Imperial (In)
Actuator
Sizes
Valve
Code
Inner Bolt Circle
Outer Bolt Circle
Stem Hole
Bolt Circle
(+/- .005)
No.
Holes
Bolt Size
Bolt Circle
(+/- .005)
No.
Holes
Bolt Size
Bore
Diameter
(+/- .004)
Across
Flats
(+ .002-.0)
Depth
Keyway Width
(+ .002-.0)
48
AA
1.42
4
#10-32
1.97
4
1/4-20
0.4
0.32
1.3
NA
63
A
1.969
4
1/4-20
2.756
4
5/16-18
0.552
0.395
1.38
NA
83
C
1.969
4
1/4-20
2.756
4
5/16-18
0.749
0.513
1.46
NA
93
C
1.969
4
1/4-20
2.756
4
5/16-18
0.749
0.513
1.46
NA
119
E
2.756
4
5/16-18
4.921
4
1/2-13
1.182
0.867
2.2
NA
128
E
2.756
4
5/16-18
4.921
4
1/2-13
1.182
0.867
2.2
NA
160A
E
NA
NA
NA
4.921
4
1/2-13
1.182
0.867
2.2
NA
160B
F
NA
NA
NA
4.921
4
1/2-13
1.38
NA
2.38
0.394
210
G
4.921
4
1/2-13
6.496
4
5/8-11
1.97
NA
2.76
0.472
255A
H
6.496
4
5/8-11
4.724 X 7.874
4
5/8-11
2.505
NA
4.25
0.625
255B
K
6.496
4
5/8-11
4.724 X 7.874
4
5/8-11
3.006
NA
4.25
0.750
Actuator Mounting Codes for S92/93 - Metric (mm)
Actuator
Sizes
Valve
Code
Inner Bolt Circle
Outer Bolt Circle
Stem Hole
Bolt Circle
(+/- .127)
No.
Holes
Bolt Size
Bolt Circle
(+/- .127)
No.
Holes
Bolt Size
Bore Dia.
(+/-.102)
Across Flats
(+ .050-.0)
Depth
Keyway
Width
48
AA
36
4
M5 x 0.8P
50
4
M6 x 1.0P
10
8
33
NA
63
A
50
4
M6 x 1.0P
70
4
M8 x 1.25P
14
10
35
NA
83
C
50
4
M6 x 1.0P
70
4
M8 x 1.25P
19
13
37
NA
93
C
50
4
M6 x 1.0P
70
4
M8 x 1.25P
19
13
37
NA
119
E
70
4
M8 x 1.25P
125
4
M12 x 1.75P
30
22
56
NA
128
E
70
4
M8 x 1.25P
125
4
M12 x 1.75P
30
22
56
NA
160A
E
NA
NA
NA
125
4
M12 x 1.75P
30
22
56
NA
160B
F
NA
NA
NA
125
4
M12 x 1.75P
35
NA
60
10
210
G
125
4
M12 x 1.75-6H
165
4
M20 x 2.5P
50
NA
70
12
255A
H
165
4
M20 x 2.5P
120 x 200
4
M20 x 2.5P
64
NA
108
16
255B
K
165
4
M20 x 2.5P
120 x 200
4
M20 x 2.5P
76
NA
108
19