Plz-3w/3wh series, Electronic load (cc·cr·cv·cp), Specifications(plz-3w series) – Atec Kikusui-PLZ1003W User Manual
Page 9
Copyright © 2001 KIKUSUI ELECTRONICS CORP. All rights reserved.
http://www.kikusui.co.jp/
Page9
■
Operating Area
PLZ153W
PLZ303W
PLZ603W
PLZ1003W
Operating
voltage (DC)
1.5 to 120 V
Current
30 A
60 A
120 A
200 A
Power
150 W
300 W
600 W
1000 W
Minimum operation-
starting voltage*1
0.3 V
*1 Current can flow in a range of 0.3 to 1.5 V. However, the specifications for this
instrument may not be met.
■
Constant Resistance Mode
PLZ153W
PLZ303W
PLZ603W
PLZ1003W
Operating range
0.1 to 10
Ω
0.05 to 5
Ω
0.025 to 2.5
Ω
0.015 to 1
Ω
Range H*4
10 to 0.1 S
20 to 0.2 S
40 to 0.4 S
66 to 1 S
1 to 100
Ω
0.5 to 50
Ω
0.25 to 25
Ω
0.15 to 10
Ω
Range L*4
1 to 0.01 S
2 to 0.02 S
4 to 0.04 S
6.6 to 0.1 S
Setting resolution
Range H*5
0.25 mS
0.5 mS
1 mS
2.5 mS
Range L*5
0.025 mS
0.05 mS
0.1 mS
0.25 mS
Setting accuracy
(current conversion)*1
±
(1% of rated current +
α
)*3
Stability
DC input voltage regulation*2
6%
±
(1000 ppm/
°
C + 1 m
Ω
/
°
C)
Temperature coefficient
at minimum resistance value
Ripple noise
Complies with graph 1 (typical values)
*1 In a range of 23
±
5
°
C and at 3 V input voltage
*2 With respect to an input voltage change of 1.5 V to 3.0 V at the minimum resistance
value. For other resistance, the voltage variations will be within 6% of the maximum
conductance (S) value of the setting range with respect to variations in all input volt-
ages. (These values were obtained with the load terminals remote sensed.)
*3
α
= 3 V
÷
set resistance - 3 V
÷
(set resistance + 8 m
Ω
)
*4 S:siemens
*5 mS: millisiemens
Note: Conductance (S) x input voltage (V) = load current (A)
Conductance (S) = 1/resistance (
Ω
)
■
Constant Current Mode
PLZ153W
PLZ303W
PLZ603W
PLZ1003W
Operating range
Range H
0 to 30A
0 to 60A
0 to 120 A
0 to 200 A
Range L
0 to 3 A
0 to 6 A
0 to 12 A
0 to 20 A
Setting accuracy
(with respect to rated
±
(0.3%
±
(0.3%
±
(0.3%
±
(0.3%
current)*1
+ 30 mA)
+ 60 mA)
+ 120 mA)
+200 mA)
Setting resolution
Range H
8 mA
15 mA
30 mA
60 mA
Range L
0.8 mA
1.5 mA
3 mA
6 mA
Stability
Line regulation*2
3 mA
DC input voltage
regulation*3
10 mA
Temperature coefficient
±
100 ppm/
°
C of rated current (typical value)
Ripple noise*4
RMS*5
3 mA
5 mA
10 mA
20 mA
Measuring current*6
At 30 A
At 60 A
At 100 A
At 100 A
Peak-to-peak
30 mA
30 mA
50 mA
100 mA
Measuring current
At 30 A
At 60 A
At 100 A
At 100 A
*1 In a range of 23
±
5
°
C
*2 With respect to a variation of
±
10% of the center value of input supply voltage at the
rated current of 5 V input voltage
*3 Value obtained when input voltage is varied from 1.5 V to 120 V at the current of rated
power/120 V
*4 At the rated current of 1.5 V input voltage
*5 5 Hz to 500 kHz
*6 DC to 15 MHz
PLZ-3W/3WH series
ELECTRONIC LOAD (CC·CR·CV·CP)
Specifications(PLZ-3W series)
■
Constant Voltage Mode
PLZ153W
PLZ303W
PLZ603W
PLZ1003W
Operating range (DC)
1.5 V to 120 V
Setting accuracy*1
±
0.1% of rated voltage
Setting resolution
30 mV
DC input current
regulation*2
±
0.01% of rated voltage
Temperature
coefficient
±
100 ppm/
°
C of rated voltage (typical value)
*1 In a range of 23
±
5
°
C (with load terminal remote sensing)
*2 With respect to a change in the input current of 10% to 100% of the rated current at 1.5
V input voltage (with load terminal remote sensing)
■
Constant Power Mode
PLZ153W
PLZ303W
PLZ603W
PLZ1003W
Operating range (DC)
15 to 150 W
30 to 300 W
60 to 600 W 100 to 1000 W
Setting accuracy*1
±
2% of rated power
Setting resolution
0.025% of rated power
DC input voltage
regulation*2
2% of rated power
Ripple current*3
Complies with graph 2 (typical values)
Temperature
coefficient
±
1000 ppm/
°
C of rated power (typical value)
*1 In a range of 23
±
5
°
C and at 5 V input voltage (with load terminal remote sensing)
*2 With respect to an input voltage change of 6 V to 120 V at rated power (with load
terminal remote sensing)
*3 When the ripple noise of input voltage is 5 mV or less
■
Tr/Tf, Switching and Soft-start Operations, Remote Sensing, and Protective Features
PLZ153W
PLZ303W
PLZ603W
PLZ1003W
Tr/Tf setting*1
Operation mode
Constant current
Setting range 50, 100, 200, 500
µ
s
1, 2, 5, 10 ms
Setting accuracy*2
±
30% of set value,
±
15
µ
s
Switching operation
Operation mode
Constant current, constant resistance
Time setting range
1 to 5000 ms
Time setting accuracy
±
5% of set value
Soft-start operation
Operation mode
Constant current(C.C)
Setting range
0.1, 1, 2, 5, 10, 20, 50, 100 ms
Setting accuracy
±
30% of set value,
±
100
µ
s
Remote sensing
Sensing voltage
5 V*3
Protective features
Over current protection
(OCP)
Limit is activated at about +5% of rated current.
Overheat protection
Load current is cut off at a heat sink
(OHP)
temperature of about 105
°
C.
Reverse connection
protection
With diodes and fuses
Power transistor
protection
With fuses
Overvoltage protection
(OVP)
Load switch will be turned off.
*1 In an input voltage range of 3 V to 120 V.
Rise time (Tr) and fall time (Tf) are times required to reach 10% to 90% of current
waveform.
*2 Tr/Tf setting is valid when the range of changes in load current is 2% to 100% of the
rated current value.
*3 2.5 V at one terminal