Plz-3w/3wh series, Electronic load (cc·cr·cv·cp), Front panel – Atec Kikusui-PLZ1003W User Manual
Page 2: Rear panel
Copyright © 2001 KIKUSUI ELECTRONICS CORP. All rights reserved.
http://www.kikusui.co.jp/
Page2
Front Panel
PLZ-3W/3WH series
ELECTRONIC LOAD (CC·CR·CV·CP)
PLZ303WH
Rear Panel
11
15
14
12
13
1 Load terminals on the front panel
Used to connect to the device being tested. They are connected in paral
lel to the load terminals on the rear panel. (Note that PLZ603W/603WH
and PLZ1003W/1003WH have no load terminals on the front panel.)
2 LOAD key
Turns on/off current that flows through the instrument.
3 Screen (LCD with back light)
Displays the set values of current, resistance, voltage, and power; menu
items; and a variety of parameters and messages.
4 Constant current (C.C) / constant resistance (C.R) lamps
Indicate whether the instrument is in C.C or C.R mode.
5 Function keys
Used to select each mode, or to set memories or rise/fall time.
6 JOG/SHUTTLE knobs
The JOG knob is used for fine adjustments to set values or to select val
ues, and the SHUTTLE knob is used for coarse adjustments to set values.
7 Arrow keys
Used to select a menu, setting item, or a step number for program editing
in the sequence mode.
8 Sequence keys
Menu keys for sequence mode
9 Memory card slot
An optional memory card (SMC-32) is inserted here.
10 Contrast control
11 Optional board slot
An optional interface board (one of GPIB, RS-232C, and MCB) is in
serted here.
12 Remote sensing terminals
Used for remote sensing that compensates for the voltage drop caused by
resistance in load cabling.
13 External control connector
14 Load terminals
15 AC input supply voltage range selector switch (on the bottom face)
8
9
10
2
1
3
4
5
6
7
PLZ303WH