Plz-3w/3wh series, Electronic load (cc·cr·cv·cp) – Atec Kikusui-PLZ1003W User Manual

Page 4

background image

Copyright © 2001 KIKUSUI ELECTRONICS CORP. All rights reserved.

http://www.kikusui.co.jp/

Page4

PLZ-3W/3WH series

ELECTRONIC LOAD (CC·CR·CV·CP)

Three-memory function and switching function

Individual set values can be stored in three memories [A], [B], and
[C] and can be recalled freely. For the C.C and C.R modes, the instru-
ments have a switching function that recalls these values from the
memories in the order [A], [B], [C], [A], [B], [C], .... and executes
them repeatedly.

Soft-start function that suppresses output voltage distortion

The start-up time of the instruments can be changed in accordance
with the output-voltage rise time for the device being tested. This
allows them to conduct tests which more closely approximate real-
world conditions.
(Soft-start time: Selectable from 0.1, 1, 2, 5, 10, 20, 50, and 100 ms)
Note: In case of PLZ-3WH series, selectable from 0.5ms.

Memory card that allows significantly improved operability

Data set from the front panel or through GPIB can be saved in the
optional memory card. Using this card, other sections such as pro-
duction and inspection lines can easily recall setup data and set up
current simulation data.

To Meet More Expanding Applications

Switching waveform
(in C.C mode)
H: 5 ms/div, V: 10A/div
Memory A 0 A, 12 ms
Memory B 30 A, 10 ms
Memory C 59 A, 15 ms

Rated capacities in parallel operations

Model

For 2 units

For 3 units

For 4 units

For 5 units

PLZ153W

300W,60A

450W,90A

600W,120A

750W,150A

PLZ303W

600W,120A

900W,180A

1200W,240A

1500W,300A

PLZ603W

1200W,240A

1800W,360A

2400W,480A

3000W,600A

PLZ1003W

2000W,400A

3000W,600A

4000W,800A

5000W,1000A

PLZ153WH

300W,15A

450W,22.5A

600W,30A

750W,37.5A

PLZ303WH

600W,30A

900W,45A

1200W,60A

1500W,75A

PLZ603WH

1200W,60A

1800W,90A

2400W,120A

3000W,150A

PLZ1003WH

2000W,100A

3000W,150A

4000W,200A

5000W,250A

Short-circuit function that allows instantaneous setting of the

maximum current

During operations in C.C or C.R mode, pressing the SHORT key al-
lows you to set either the maximum current value (in C.C mode) or
minimum resistance value (in C.R mode) of the range instantaneously,
without using the JOG or SHUTTLE key. In addition, when a large-
current relay or other element is connected to the external control
connector as shown below, if the voltage at the load terminals falls
below approximately 1.5 V, the load terminals will be in a short-cir-
cuit state. This allows the instruments to perform effectively at cur-
rents of 1.5 V or less during current-limiting drooping characteristic
tests of DC power supplies.

DC power supply start-up time

Electronic load start-up time

Time

Example where soft-start is not used

Time

Example where soft-start is used

+

_

+

_

Device being tested

PLZ-3W/3WH

Series

Large-current relay

Buffer

Parallel operations that offer increased current and power

capacities

The PLZ-3W/3WH Series allow parallel connection of identical mod-
els in order to increase current and power capacities. In parallel op-
erations, a single master unit can control multiple slaves, such as set-
ting total current for all. Naturally, the total current is also displayed
on the monitors. A maximum of five instruments can be operated in
parallel.

To Support Today’s More Diverse Experiments and Tests

Memory card (SMC-32)

* Please order parallel operation cable (model PC01-PLZ-3W) when connecting the
PLZ-3W/3WH Series in parallel.