Plz-3w/3wh series, Electronic load (cc·cr·cv·cp) – Atec Kikusui-PLZ1003W User Manual
Page 4
Copyright © 2001 KIKUSUI ELECTRONICS CORP. All rights reserved.
http://www.kikusui.co.jp/
Page4
PLZ-3W/3WH series
ELECTRONIC LOAD (CC·CR·CV·CP)
●
Three-memory function and switching function
Individual set values can be stored in three memories [A], [B], and
[C] and can be recalled freely. For the C.C and C.R modes, the instru-
ments have a switching function that recalls these values from the
memories in the order [A], [B], [C], [A], [B], [C], .... and executes
them repeatedly.
●
Soft-start function that suppresses output voltage distortion
The start-up time of the instruments can be changed in accordance
with the output-voltage rise time for the device being tested. This
allows them to conduct tests which more closely approximate real-
world conditions.
(Soft-start time: Selectable from 0.1, 1, 2, 5, 10, 20, 50, and 100 ms)
Note: In case of PLZ-3WH series, selectable from 0.5ms.
●
Memory card that allows significantly improved operability
Data set from the front panel or through GPIB can be saved in the
optional memory card. Using this card, other sections such as pro-
duction and inspection lines can easily recall setup data and set up
current simulation data.
To Meet More Expanding Applications
Switching waveform
(in C.C mode)
H: 5 ms/div, V: 10A/div
Memory A 0 A, 12 ms
Memory B 30 A, 10 ms
Memory C 59 A, 15 ms
Rated capacities in parallel operations
Model
For 2 units
For 3 units
For 4 units
For 5 units
PLZ153W
300W,60A
450W,90A
600W,120A
750W,150A
PLZ303W
600W,120A
900W,180A
1200W,240A
1500W,300A
PLZ603W
1200W,240A
1800W,360A
2400W,480A
3000W,600A
PLZ1003W
2000W,400A
3000W,600A
4000W,800A
5000W,1000A
PLZ153WH
300W,15A
450W,22.5A
600W,30A
750W,37.5A
PLZ303WH
600W,30A
900W,45A
1200W,60A
1500W,75A
PLZ603WH
1200W,60A
1800W,90A
2400W,120A
3000W,150A
PLZ1003WH
2000W,100A
3000W,150A
4000W,200A
5000W,250A
●
Short-circuit function that allows instantaneous setting of the
maximum current
During operations in C.C or C.R mode, pressing the SHORT key al-
lows you to set either the maximum current value (in C.C mode) or
minimum resistance value (in C.R mode) of the range instantaneously,
without using the JOG or SHUTTLE key. In addition, when a large-
current relay or other element is connected to the external control
connector as shown below, if the voltage at the load terminals falls
below approximately 1.5 V, the load terminals will be in a short-cir-
cuit state. This allows the instruments to perform effectively at cur-
rents of 1.5 V or less during current-limiting drooping characteristic
tests of DC power supplies.
DC power supply start-up time
Electronic load start-up time
Time
Example where soft-start is not used
Time
Example where soft-start is used
+
_
+
_
Device being tested
PLZ-3W/3WH
Series
Large-current relay
Buffer
●
Parallel operations that offer increased current and power
capacities
The PLZ-3W/3WH Series allow parallel connection of identical mod-
els in order to increase current and power capacities. In parallel op-
erations, a single master unit can control multiple slaves, such as set-
ting total current for all. Naturally, the total current is also displayed
on the monitors. A maximum of five instruments can be operated in
parallel.
To Support Today’s More Diverse Experiments and Tests
Memory card (SMC-32)
* Please order parallel operation cable (model PC01-PLZ-3W) when connecting the
PLZ-3W/3WH Series in parallel.