PLZ-3W/3WH series

ELECTRONIC LOAD (CC·CR·CV·CP)

Actual-load simulations

The sequence function is used to capture real waveform data into the
memory card. This allows actual-load simulations to be conducted.

Capturing Data:
The load current of a motor is captured using an oscilloscope, and
the waveform data is saved in the memory card of the PLZ-3W/
3WH through the GPIB interface.
Calling the data:
As the data stored in the memory card is available even when the
GPIB interface is disconnected, you can do actual-load simulations
in test lines or without integrating a complicated system.

Applications

Automatic test system for DC current

Combining the PLZ-3W/3WH Series with a Kikusui PCR-L Series
AC power supply allows you to configure an automatic test system
for switching power supplies.

AC input side test ... PCR-L Series:

● Power line abnormality simulations
● AC line regulation tests
● Instantaneous power failure tests and others

DC roading test ... PLZ-3W/3WH Series:

● Loading simulations
● Load regulation tests
● Transitional response tests
● Current-limiting characteristic tests and others

GPIB

Contoroller

PCR-L Series for setting

input conditions

AC power

Switching power

supply

PLZ-3W/3WH Series for

setting loading conditions

Digital oscilloscope Data acquisition

by the COR5500U Series or other models

I

I

GPIB

DC power supply

Motor or other equipment

Storing waveform

Controller

Data transfer

COR5500U Series digital oscilloscope

or other models

Transferring to

memory card

PLZ-3W/3WH

Series

Memory card

Disconnecting the GPIB interface

Memory card

DC power supply

PLZ-3W/3WH Series