Pcr-l series, Multi purpose ac power supply (cv·cf), Options – Atec Kikusui-PCR500L User Manual
Page 8

Page8
Copyright © 2002 KIKUSUI ELECTRONICS CORP. All rights reserved.
http://www.kikusui.co.jp/
■
Remote Controller (RC02-PCR-L)
The remote controller allows each of the functions on the
control panel of members of the PCR-L/LT series to be
manipulated while away from the control panel. Moreover, this
remote controller is composed of options for expanding
functions, including harmonics
current analysis, power line
irregularity simulation and
sequence operation, a remote
controller box a remote
controller card (inserted into a
slot in the main unit) and a
remote controller cable
(length:2m).
■
GPIB Interface(IB11-PCR-L)
The GPIB interface for the members of the
PCR-L/LT series allows programmable control
of the functions on the power supply control
panel as well as nearly all the expansion
functions available by using the RC02-PCR-L
remote controller. This interface also performs
readout of measured values.
■
RS-232C Interface (RS11-PCR-L)
The RS-232C interface for the PCR-L/LT
series allows readout of measured values and
programmable control of the functions on the
power supply control panel as well as nearly
all the expansion functions available by using
the RC02-PCR-L remote controller.
■
Centrally Controlled Parallel Operation Driver
(PD02M-PCR-L/PD02S-PCR-L)
This option card is for expanding the
output capacity of members of the
PCR-L series by means of parallel
operation. This card is applicable to the
combinations shown at right.
*Some modification may be required
depending on the version of the power
supply main unit.
Note: In this application, the ROM version of the PCR-L series
must be Ver.2.00 or later.
■
Three-Phase Output Driver (3P02-PCR-L)
This option card is for
expanding the output of
members of the PCR-L series
to a three-phase output. This
card is applicable to the
combinations shown at right.
*Some modification may be
required depending on the
version of the power supply
main unit.
Note1: In this application, the ROM version of the PCR-L se-
ries must be Ver.2.00 or later.
Note2: The following functions are not available when the 3-
Phase Driver is installed.
•
Power Line Irregularity
•
Simulation function
•
Current limit
value setting
•
Average voltage/current value measurement
•
Sens-
ing function
•
Regulation Adjustment function
•
DC Mode
•
AC
+ DC Mode
AC Output
✔
✔
✔
DC Output
✔
✔
✔
AC + DC Output
✔
✔
Harmonics Current Measurement
✔
✔
Power Line Irregularities Simulation
✔
✔
Sequence Operation
✔
✔
Special Waveform Output
✔
✔
User Defined Waveform Output
✔
Output ON/OFF Phase Setting
✔
✔
Output Impedance Setting
✔
✔
Memory Size (No, of Sets of Settings)
9
99
99
Regulation Adjustment
✔
Measurement Functions
RMS Value
✔
✔
✔
Output
Peak Value
✔
✔
✔
Average Value (DC Only)
✔
✔
✔
RMS Value
✔
✔
✔
Current
Peak Value
✔
✔
✔
Average Value (DC Only)
✔
✔
✔
Peak Hold Value
✔
✔
Electrical
Effective Electrical Power
✔
✔
✔
Power
Apparent Electrical Power
✔
✔
Power Factor
✔
✔
Other Functions
✔
✔
✔
Function
Power Supply
Only
Power Supply
+ RC02-PCR-L
Power Supply
+ IB11-PCR-L
or RS11-PCR-L
Combinations Required for Single-Phase Parallel Operation
PCR500L PCR1000L PCR2000L PCR4000L PCR6000L 3P02-PCR-L
PD02M-PCR-L
1.5kVA
3
1
3kVA
3
1
6kVA
3
1
12kVA
3
1
12kVA
6
1
3
18kVA
3
1
18kVA
9
1
3
24kVA
6
1
3
36kVA
6
1
3
36kVA
9
1
3
54kVA
9
1
3
Combinations Required for Three-Phase Parallel Operation
Note:Please inquire separately regarding parallel operation using 4 or more power supplies.
Output
Capacity
Parallel Operation
Driver
Three-Phase
Driver
Model
Options
Model
Parallel Operation Drive
PCR2000L
PCR4000L
PCR6000L
PD02M-PCR-L PD02S-PCR-L
4kVA
2
1
1
6kVA
3
1
2
8kVA
2
1
1
12kVA
3
1
2
12kVA
2
1
1
18kVA
3
1
2
Output
Capacity
PCR-L series
MULTI PURPOSE AC POWER SUPPLY (CV·CF)
Note:Please inquire separately regarding parallel operation using 4 or more power supplies.