Atec Fluke-Norma-4000-5000 Series User Manual
Page 3
ENEN
Automotive – Detailed analysis of all electrical and
mechanical components installed in modern cars for
developing strategies that help reduce fuel
consumption or the increase the range of electric
vehicles. Synchronous electrical input and
mechanical output measurements provide complete
data on the efficiency and losses of individual
components as well as the whole drive system.
Switching power supplies and UPS – Very wide
bandwidth enables detailed and accurate power
measurements in the switching link of switching
power supplies. Unique coaxial shunt technology
delivers precision results in high frequencies of
several 100 kHz.
Charge pumps/boost converters – Wide
measurement bandwidth combined with wide
dynamic range enable precise measurements of
charge pumps with very high switching frequency
in the link circuit.
Current transducers – Detect very small phase
shift errors between the various current and voltage
channels for support the calibration of current
transducers.
tan
δ (dissipation factor) measurement – Measure
power at very small power factors and calculate tan
δ from voltage and current at very low loss angles.
Calibration and test laboratories – High
measurement accuracy enables use as a standard
for power calibration and for the certification of
voltage, current, power and distortion.
Fast Fourier Transformation (FFT)
Calculation of harmonics with graphical
representation. Up to 3 harmonic
spectrums are displayed simultaneously.
Measured values: U, I, & P per phase.
Order: 1
st
to 40
th
harmonics, maximum
half sample frequency.
Digital Oscilloscope (DSO)
Simultaneous display of up to 3
measured values at sample level. Quick
view of waveform and distortion.
Integration function (Energy)
Simultaneous display of up to 6
configurable numeric values. Start/Stop
conditions and positive negative
direction available.
Vector display
Vector display of the fundamental for up
to 6 signals. For easy testing of the right
connection of the instrument and quick
overview of the phase angle of each
signal.
Recorder function
Display of average values over time for
trend determination.
RAM data memory
Storing of sample and average values;
setting of start and stop conditions.
From the RAM approximately 4 MB are
available for the storage of measured
values. The memory can be expanded
up to 128 MB.
Configuration
Set up the analyzer to measure and
display data in the format required.
Basic Functions
3 Fluke Corporation Analyseurs de puissance de la Fluke Norma 4000/5000