Atec Fluke-Norma-4000-5000 Series User Manual
Technical data, High precision power analyzers, Fluke norma series power analyzers at a glance
Fluke Norma 4000/5000
High Precision Power Analyzers
Reliable, highly accurate
measurements for the test &
development of power electronics
Compact Fluke Norma Series power analyzers
include the latest power measurement
technology to assist engineers working with
motors, inverters, lighting, power supplies,
transformers and automotive components in
making their products more efficient.
Based on a patented high-bandwidth
architecture, Fluke Norma Series power analyzers
deliver precise measurements of single or three-
phase current and voltage, harmonics analysis,
Fast Fourier Transformation (FFT) analysis, as well
as calculations of power and other derived
values. They provide class-leading accuracy and
common mode rejection for any waveform,
frequency, or phase shift.
Technical Data
ENEN
•
Fluke Norma 4000:
Ideal for field testing, the Fluke Norma
4000 power analyzer offers easy and
straight-forward operation. Features
include: 1 to 3 power phases, 5.7” / 144
mm color display, harmonic analysis, FFT
analysis, scope mode, vector diagram
display, recorder function, Fluke
NormaView PC software, and 4 MB RAM
data memory.
•
Fluke Norma 5000:
Providing the highest bandwidth on the
market, the Fluke Norma 5000 power
analyzer is the ideal test and analysis tool
for the development of frequency
converters and lighting equipment.
Features include: 1 to 6 power phases,
optional internal printer, and all of the
features and functionality of the Fluke
Norma 4000 power analyzer described
above.
Fluke Norma 4000
Fluke Norma 5000
Number of Phases
1 or 3
3, 4 or 6
Bandwidth
dc to 3 MHz or dc to 10 MHz depending on input
module
Basic Accuracy
0.2%, 0.1% or 0.03% depending on input
modules
Sampling Rate
0.33 MHz or 1 MHz depending on input modules
Voltage Input Range
0.3 to 1000 V
Current Input Range (direct, not via shunt)
0.03 mA – 20 A depending on input module
Display
Color, 5.7“ / 144 mm - 320 x 240 pixel
Memory for Configurations
4 MB
Memory for Settings
Standard
Fast Fourier Transformation (FFT)
To the 40
th
harmonic
RS232 Interface
Standard
PI1 Process Interface
(8 analog / impulse inputs and 4 analog
outputs)
Optional
IEEE 488/GPIB Interface
Optional
Fluke NormaView PC Software (for data
download, analysis & report writing)
Standard
Fluke Norma Series power analyzers
at a glance
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-571-8431
Visit us at www.TestEquipmentDepot.com