Specifications in brief – Atec Rohde-Schwarz-EB500 User Manual
Page 19
Rohde & Schwarz R&S®EB500 Monitoring Receiver 19
Specifications in brief
Specifications in brief
Frequency
Frequency range
base unit
20 MHz to 3.6 GHz
with R&S®EB500HF option
9 kHz to 3.6 GHz
with R&S®EB500FE option
20 MHz to 6 GHz
with R&S®EB500HF and R&S®EB500FE options 9 kHz to 6 GHz
Demodulation
Demodulation modes
all IF bandwidths
AM, FM, PM, PULSE, I/Q
IF bandwidths ≤ 9 kHz
LSB, USB, CW
IF bandwidths ≥ 1 kHz
ISB
IF bandwidths
Bandwidth
demodulation, level and offset measurements
(3 dB bandwidth), 34 filters
100/150/300/600 Hz,
1/1.5/2.1/2.4/2.7/3.1/4/4.8/6/9/12/15/30/50/
120/150/250/300/500/800 kHz,
1/1.25/1.5/2/5/8/10/12.5/15/20 MHz
IF panorama
FFT IF panorama
up to 4096point FFT
dynamic, overlapping FFT
operating modes
automatic or variable with selectable frequency
resolution
0.625/1.25/2.5/3.125/6.25/12.5/25/31.25/50/62.5/
100/125/200/250/312.5/500/625 Hz,
1/1.25/2/2.5/3.125/5/6.25/8.333/10/12.5/20/
25/50/100/200/500 kHz, 1 MHz, 2 MHz
IF panorama span
1/2/5/10/20/50/100/200/500 kHz,
1/2/5/10/20 MHz
Panorama display
clear/write, average, max. hold, min. hold
DF mode
VHF/UHF/SHF range
correlative interferometer
HF range
WatsonWatt
Scan characteristics
Memory scan
10 000 programmable memory locations
speed
up to 500 channels/s
Frequency scan
userselectable start/stop frequency and step
width
speed
up to 500 channels/s
Panorama scan
with R&S®EB500PS option
RF spectrum with userselectable start/stop
frequency and step width:
100/125/200/250/500/625 Hz,
1/1.25/2/2.5/3.125/5/6.25/8.333/10/12.5/20/
25/50/100/200/500 kHz, 1 MHz, 2 MHz
speed
up to 12 GHz/s
For data sheet, see PD 5214.3800.22 and www.rohde-schwarz.com.