Atec Agilent-60503B User Manual
Page 5
![background image](/manuals/318501/5/background.png)
6
Table 60503-1 Specifications and Supplemental Characteristics (continued)
Source Turn-On Current Overshoot:
Less than 5% of final value (in CC and CR modes when connected to power
supplies with voltage rise times of greater than 500
µ
s).
Programmable Short Circuit:
0.20
Ω
(0.10
Ω
typical)
Programmable Open Circuit:
80 k
Ω
(typical)
Drift Stability
(over an 8 hour interval):
Current:
±0.03% ±1.5 mA
Voltage:
±0.01% ±20 mV
Reverse Current Capacity:
20 A when unit is on; 10 A when unit is off
Weight:
3.2 kg (7 lbs.)
Table 60503-2. Programming Ranges
Function
Front Panel
Front Panel
HPSL Command
Range of Values
Key
Display
(Short Form)
Constant Current
Set Range
C:RNG value
"CURR:RANG value"
Low Range
≥
0 and
≤
1 A
High Range
> l A and
≤
10 A
Set Main Level
CURR value
"CURR value"
Low Range
0 to 1 A
High Range
0 to 10 A
Set Slew Rate
(shift)
C:SLW value
"CURR:SLEW value"
Low Range
0.000007 to .083 (A/
µ
s)
High Range
0.00017 to 0.83 (A/
µ
s)
Set Transient Level
C:TLV value
"CURR:TLEV value"
same as main level
*Set Triggered Level
"CURR:TRIG value"
same as main level
Constant Resistance
Set Range
R:RNG value
"RES:RANG value"
Low Range
≥
0 and
≤
24
Ω
Middle Range
> 24
Ω
and
≤
24 k
Ω
High Range
>24 k
Ω
and
≤
24 k
Ω
Set Main Level
RES value
"RES value"
Low Range
0 to 24
Ω
Middle Range
24
Ω
to 24 k
Ω
High Range
240
Ω
to 240 k
Ω
Set Slew Rate
(shift)
Low Range
V:SLW value
"VOLT:SLEW value"
same as voltage slew
Middle/High Range
C:SLW value
"CURR:SLEW value"
same as current slew
Set Transient Level
R:TLV value
"RES:TLEV value"
same as main level
*Set Triggered Level
"RES:TRIG value"
same as main level
Constant Voltage
Set Main Level
VOLT value
"VOLT value"
0 to 240 V
Set Slew Rate
(shift)
V:SLW value
"VOLT:SLEW value"
0.004 to 2 (V/
µ
s)
Set Transient Level
V:TLV value
"VOLT:TLEV value"
same as main level
*Set Triggered Level
"VOLT:TRIG value"
same as main level