beautypg.com

Atec Agilent-60503B User Manual

Page 5

background image

6

Table 60503-1 Specifications and Supplemental Characteristics (continued)

Source Turn-On Current Overshoot:

Less than 5% of final value (in CC and CR modes when connected to power

supplies with voltage rise times of greater than 500

µ

s).

Programmable Short Circuit:

0.20

(0.10

typical)

Programmable Open Circuit:

80 k

(typical)

Drift Stability

(over an 8 hour interval):

Current:

±0.03% ±1.5 mA

Voltage:

±0.01% ±20 mV

Reverse Current Capacity:

20 A when unit is on; 10 A when unit is off

Weight:

3.2 kg (7 lbs.)

Table 60503-2. Programming Ranges

Function

Front Panel

Front Panel

HPSL Command

Range of Values

Key

Display

(Short Form)

Constant Current

Set Range

C:RNG value

"CURR:RANG value"

Low Range

0 and

1 A

High Range

> l A and

10 A

Set Main Level

CURR value

"CURR value"

Low Range

0 to 1 A

High Range

0 to 10 A

Set Slew Rate

(shift)

C:SLW value

"CURR:SLEW value"

Low Range

0.000007 to .083 (A/

µ

s)

High Range

0.00017 to 0.83 (A/

µ

s)

Set Transient Level

C:TLV value

"CURR:TLEV value"

same as main level

*Set Triggered Level

"CURR:TRIG value"

same as main level

Constant Resistance

Set Range

R:RNG value

"RES:RANG value"

Low Range

0 and

24

Middle Range

> 24

and

24 k

High Range

>24 k

and

24 k

Set Main Level

RES value

"RES value"

Low Range

0 to 24

Middle Range

24

to 24 k

High Range

240

to 240 k

Set Slew Rate

(shift)

Low Range

V:SLW value

"VOLT:SLEW value"

same as voltage slew

Middle/High Range

C:SLW value

"CURR:SLEW value"

same as current slew

Set Transient Level

R:TLV value

"RES:TLEV value"

same as main level

*Set Triggered Level

"RES:TRIG value"

same as main level

Constant Voltage

Set Main Level

VOLT value

"VOLT value"

0 to 240 V

Set Slew Rate

(shift)

V:SLW value

"VOLT:SLEW value"

0.004 to 2 (V/

µ

s)

Set Transient Level

V:TLV value

"VOLT:TLEV value"

same as main level

*Set Triggered Level

"VOLT:TRIG value"

same as main level