beautypg.com

Atec Agilent-60503B User Manual

Atec Equipment

background image

2

Table 60503-1. Specification and Supplemental Characteristics

SPECIFICATIONS

DC Input Rating:

Current:

0 to 10 A

Voltage

: 3 V to 240 V (minimum dc operation from 0 to 2 V for 0 to 10 A)

Power:

250 W at 40

°

C (derated to 187 W at 55

°

C)

A. OPERATING CHARACTERISTICS B. DERATED CURRENT DETAIL

Constant Current Mode:

Ranges:

0 to 1 A; and 0 to 10 A

Accuracy:

(after 30 second wait):

±

0.15% ± 10 mA (both ranges)

Resolution:

0.26 mA (1 A range); 2.6 mA (10 A range)

Regulation:

8 mA (both ranges)

Temperature Coefficient:

150 ppm/

°

C ± l mA/

°

C (both ranges)

Constant Resistance Mode:

Ranges:

0.20 to 24

; 24

to 10 k

; and 240

to 50 k

Accuracy:

± 0.8% ± 200 m

with

1 A at input (24

range);

± 0.3% ± 0.3 mS with

24 V at input (10 k and 50 k

ranges)

Resolution:

6 m

(24

range); 0.011 mS (10 k

range); 0.001 mS (50 k

range)

Regulation:

10 mV with remote sensing (24

range); 8 mA (10 k and 50 k

ranges)

Temperature Coefficient:

800 ppm/

°

C ± 10 m

/

°

C (24

range);

300ppm/

°

C ± 0.03 mS/

°

C (10 k and 50 k

ranges)

Constant Voltage Mode:

Range:

0 to 240 V

Accuracy:

± 0.12% ± 120 mV

Resolution:

64 mV

Regulation:

10 mV (remote sense); 40 mV (local sense)

Temperature Coefficient:

120 ppm/

°

C ± 10 mV/

°

C