Supplemental characteristics for all model numbers – Atec Agilent-6570A Series User Manual
Page 5

5
Agilent models: 6571A, 6572A, 6573A, 6574A, 6575A
425.5 mm
16.75"
574 mm
22.6"
640 mm
25.4"
68 mm
2.67"
132.6 mm
5.2"
145.1 mm
5.71"
12.7 mm
0.5"
128 mm
5.04"
Accepts wire
AWG 12-22
1/4" x 1" untreaded
hole on each bussbar
Note: Buss bar is 1/8" thick cu
1.25"
0.75"
0.31 dia"
1.0"
0.5"
IM
VP
+IP
-IP
+P
+S
-S
-LS
+LS
Top
Side
Rear
Rear connector detail
Buss bar detail
Supplemental characteristics
for all model numbers
DC floating voltage: Output terminals
can be floated up to ± 240 VDC from
chassis ground
Output common-mode noise current:
(to signal ground binding post)
500 μA rms, 4 mA peak-to-peak
Remote sensing: Up to half the rated
output voltage can be dropped in each
load lead. The drop in the load leads
subtracts from the voltage available
for the load.
Modulation: (Analog programming of
output voltage and current)
Input signal: 0 to –4 V for voltage,
0 to 7 V for current
Input impedance: 30 kΩ or greater
Input power: 3,800 VA, 2,600 W at full
load; 170 W at no load
Regulatory compliance: Listed to
UL1244; certified to CSA556B; conforms
to IEC 61010-1
Size:
425.5 mm W x 132.6 mm H x 640 mm D
(16.75 in x 5.22 in x 25.2 in)
Weight: Net, 28.2 kg (62 lb);
shipping, 31.8 kg (70 lb)
Warranty: One year