General data (all models) – Atec EM-Test-Netwave-3-Phase Series User Manual
Page 3
![background image](/manuals/318413/3/background.png)
DATA SHEET > NetWave Series 3-phase > 20130606
TECHNICAL DETAILS
GENERAL DATA (ALL MODELS)
SPECIFICATIONS
Output frequency
DC - 5,000Hz
Frequency
accuracy, stability
100ppm
Output connectors
Safety lab connectors
CEE type 32A (only for NetWave 20.x
and NetWave 30.x)
Interfaces
GPIB
Ethernet
RS 232 (input from DPA analyser)
Frame bus (internal system bus)
REGULATION
Voltage sense
Internal or external, 4 wires
Distortion (THD)
Less than 0.5%, @50/60Hz
Output voltage
Stability
Better than 0.1%
Output voltage
Accuracy
Better than 0.5%
Max.
compensatable
drop on wires
5% f.s.
Current limiter
5A to Imax
Protection
Over current
Over voltage
Over temperature
Low voltage
WAVEFORM GENERATOR
Segment types DC
DC, Ramp, Square, Triangle,
Sawtooth, Step, Sine, Sine sweep,
Sine ramp, Damped sinewave, Sine
ripple, Profile, Square sweep, Noise,
Sine Dwell, Sinc, Harmonic,
Exponent ...
Segment types AC
Sine, Modulation, Sine sweep,
Sweep on Sine, Sine up/down, Sine
unbalance, Overswing, Sine offset,
Sine Dip, Harmonic, Interharmonic,
Interharmonic step, Harmonic
distortion ...
Segment duration
Unlimited
TRIGGER AND DUT MONITORING
Trigger
2 inputs, 2 outputs
DUT monitors
2 inputs, configurable
GENERAL DATA (ALL MODELS)
DISPLAY AND CONTROLS
Display
2-Line LCD, 40 characters
LED indicators
Power On
Active output channel
Trigger
Functional status hard disk
Operation
6 function keys,
Test On key: ON/OFF key for the
power source
DIMENSIONS (ROLLS AND CRANE SUPPORT INCLUDED)
NetWave 20.x
approx. 1785 x 930 x 755mm
approx. 1785 x 1210 x 755mm
(recovery)
NetWave 30.x
approx. 1785 x 930 x 755mm
approx. 1785 x 1210 x 755mm
(recovery)
NetWave 60.x
approx. 2080 x 1205 x 970mm
approx. 2080 x 1615 x 970mm
(recovery)
WEIGHT (ROLLS AND CRANE SUPPORT INCLUDED)
NetWave 20.x
approx. 740kg
approx. 810kg (recovery)
NetWave 30.x
approx. 740kg
approx. 810kg (recovery)
NetWave 60.x
approx. 1,180kg
approx. 1,380kg (recovery)
MAINS
Supply voltage
3 x 400V (3P,N,PE);
optional 3 x 208V (3P,N,PE)
Input current
50A/90A (NetWave 20.x)*
70A/140A (NetWave 30.x)*
140A/212A (NetWave 60.x)*
* the higher figure represents the 3s
short-term current
Line frequency
45Hz - 65Hz
Connectors
Screwed terminals
AMBIENT CONDITIONS
Temperature
0°C - 40°C
Rel. humidity
10% - 90%, non condensing
www.emtest.com
© EM TEST > PAGE 3/6