BTS Master™ MT8220T
Power Meter
General
Frequency
Center/Start/Stop, Span, Frequency Step, Signal Standard, Channel #, Full Band
Amplitude
Maximum, Minimum, Offset, Relative On/Off, Units, Auto Scale
Average
Acquisition Fast/Med/Slow, # of Running Averages
Limits
Limit On/Off, Limit Upper/Lower
Frequency Range
10 MHz to 7.1 GHz
Span
1 kHz to 100 MHz
Display Range
–140 dBm to +30 dBm, ≤ 40 dB span
Measurement Range
–120 dBm to +30 dBm
Offset Range
0 to +100 dB
VSWR
1.5:1 typical
Maximum Power
+30 dBm without attenuator
Accuracy
Same as Spectrum Analyzer
Application Options
Impedance (50 Ω, 75 Ω, Other)
GPS Receiver
General
Setup
On/Off, Antenna Voltage 3.3 V/5.0 V, GPS Info
GPS Time/Location Indicator
Time, Latitude, Longitude and Altitude on display
Time, Latitude, Longitude and Altitude with trace storage
High Frequency Accuracy
Spectrum Analyzer, Interference Analyzer, Wireless Measurements
when GPS Antenna is connected:
± 2.5
×
10
–8
with GPS On, 3 minutes after satellite lock in selected mode
GPS Lock Accuracy
after antenna is disconnected:
± 5.0
×
10
–8
for 3 days, 0 ºC to 50 ºC ambient temperature
Connector
SMA, female
Supplied Antenna
2000-1760-R GPS Antenna, SMA(m), 25 dB gain, 2.5 VDC to 3.7 VDC
High Accuracy Power Meter (Option 0019)
(Requires external USB Power Sensor)
Amplitude
Maximum, Minimum, Offset, Relative On/Off, Units, Auto Scale
Average
# of Running Averages, Max Hold
Zero/Cal
Zero On/Off, Cal Factor (Center Frequency, Signal Standard)
Limits
Limit On/Off, Limit Upper/Lower
Power Sensor Model
PSN50
MA24105A
MA24106A
MA24108A/18A/26A
Description
High Accuracy
RF Power Sensor
Inline High
Power Sensor
High Accuracy
RF Power Sensor
Microwave USB
Power Sensor
Frequency Range
50 MHz to 6 GHz
350 MHz to 4 GHz
50 MHz to 6 GHz
10 MHz to 8/18/26 GHz
Connector
Type N(m), 50 Ω
Type N(f), 50 Ω
Type N(m), 50 Ω
Type N(m), 50 Ω
(8/18 GHz)
Type K(m), 50 Ω
(26 GHz)
Dynamic Range
–30 dBm to +20 dBm
(0.001 mW to 100 mW)
+3 dBm to +51.76 dBm
(2 mW to 150 W)
–40 dBm to +23 dBm
(0.1 µW to 200 mW)
–40 dBm to +20 dBm
(0.1 µW to 100 mW)
VBW
100 Hz
100 Hz
100 Hz
50 kHz
Measurand
True-RMS
True-RMS
True-RMS
True-RMS, Slot Power,
Burst Average Power
Measurement Uncertainty
± 0.16 dB
1
± 0.17 dB
2
± 0.16 dB
1
± 0.18 dB
3
Data sheet
(for complete specifications)
11410-00414
11410-00621
11410-00424
11410-00504
Notes:
1. Total RSS measurement uncertainty (0 ºC to 50 ºC) for power measurements of a CW signal greater than –20 dBm with
zero mismatch errors.
2. Expanded uncertainty with K = 2 for power measurements of a CW signal greater than +20 dBm with a matched load.
Measurement results referenced to the input side of the sensor.
3. Expanded uncertainty with K = 2 for power measurements of a CW signal greater than –20 dBm with zero mismatch
errors.