beautypg.com

0 installation, 1 enclosure installation – Alpha Technologies APB HFC Voltage Booster User Manual

Page 9

background image

9

016-559-B0-001 Rev. A

2.0 Installation

2.1 Enclosure

Installation

2.1.1 Strand

Mounting

Tools Required:

• 1/2”

Socket

0-100 in-lb torque wrench

Procedure:

1. Loosen the two strand clamps on the enclosure. Ensure that the side labeled "INPUT" is facing the

correct direction.

2. Place the strand wire under the clamp plates and torque the bolts to 75 in-lbs.

3. Ensure that the output voltage is confi gured properly. Refer to section 2.2 if the output voltage requires

changing.

4. Prepare the coaxial connector(s) as outlined in Section 2.3, "Cable Preparation". Install the

connector(s) and tighten to proper torque supplied by the manufacturer.

Strand Wire

Strand Clamps

Strand Clamps

Side View

Top View