2.11.2 Transformer Replacement Procedure

1. Unplug transformer connector from J1 of the PCB.

2. Unplug transformer quick connects from Confi guration (P1) and P4 of the PCB. Note which

connector is attached to the Confi guration male connector (LOG63 or LOG87).

3. Remove nuts at "3" (4 places).

4. Remove

transformer.

5. Install new transformer with nuts at "3" (4 places).

6. Plug the connector from step 2 into the Confi guration male connector (P1). Plug the other

unused connector into P4.

7. Plug the transformer connector into J1 of the PCB.

2.0 Installation,

continued

2.11

Voltage Booster Service, continued

Tools Required:

• 11/32

Nutdriver

There will be up to 90Vac present on the PCB when a live connector is plugged into the
input or output connectors.