beautypg.com

4 connecting the coaxial cable, 0 installation, continued – Alpha Technologies PME Series User Manual

Page 35

background image

35

031-161-B0-006, Rev. F

2.0 Installation,

continued

2.4 Connecting the Coaxial Cable

2.4.1 Coaxial Cable Surge Protector Installation Instructions

Alpha recommends using coaxial surge suppression for enclosure protection. The
Coax Surge Protector with Ground Block (Alpha P/N 745-910-21) includes 75 ohm
surge suppressor, mounting hardware, and waterproofi ng grommet.

Required Tools:

Drill with 3/16" (4.8mm) bit. For older enclosures a 3/4" (19mm) bit is also

needed.

• Phillips

screwdriver

3/8" (9.5mm) socket and driver

1. Drill two 3/16" (4.8mm) holes 1½" (38.1mm) apart (indicated locations are

recommended). Newer enclosures have center punch marks on the left and right
side of the enclosure.

2. Attach the surge protector to the inside of the enclosure wall with provided

hardware. For proper grounding, ensure the included star washers come in
contact with the enclosure wall.

3. On newer enclosures, knock out one of the 3/4" (19mm) knockouts located in

the upper rear of the enclosure. On older enclosures, drill a 3/4" (19mm) hole
in desired location. Press the grommet into the hole from the outside of the
enclosure.

4. Cut center of grommet and insert coaxial cable.

5. Pull cable back to form seal.

¾"

Cut center

Grommet Installation

SERVICE

CUSTOMER

r

e

m

o

t

s

u

C

e

c

i

v

r

e

S

3/4" (19mm)

Knockouts

(for grommet)

1.5"
(38.1mm)

4"
(101.6mm)

6.5" to 7.25"

(165.1mm to 184.2mm)

This manual is related to the following products: