7. APPENDIX

41

1. INTRODUCTION

Unpacking and Inspection

The Intelligent Interface Device, standard with the CFR 7.5K, CFR 10K,

and CFR 15K, requires no installation. It is optional on all other CFR units
and comes either factory installed or as a user-installable kit. Note: The
Intelligent Interface Device is not user-installable on the CFR 600 or CFR
1000. If the unit is going to be used in a remote application, it simply plugs
into the MMJ connector located on the back of all CFR units.

If ordered separately, carefully remove the Intelligent Interface Device Kit

from its shipping container. Inspect the contents. If items appear to be
damaged or missing, contact Alpha Technologies and the shipping company
immediately. Most shipping companies have only a short claim period. Make
sure the following items have been included:

1. Intelligent Interface Device
2. Operator's Manual
3. Any other ordered options (i.e., interface cables, etc.)

SAVE THE ORIGINAL SHIPPING CONTAINER.

In the event the unit needs to be returned for service, it should be

packaged in its original shipping container. If the original container is not
available, make sure that the unit is packed with at least three inches of
shock-absorbing material to prevent shipping damage. Note: Do not use
popcorn-type material. Alpha Technologies is not responsible for damage
caused by the improper packaging of returned units.

PLEASE READ THE OPERATOR'S MANUAL.

Become familiar with the Intelligent Interface Device by reviewing the

drawings and illustrations contained in the manual before proceeding. If you
have questions regarding the safe installation or operation of the unit, contact
Alpha Technologies.

The menu items outlined in this manual can be accessed by pressing the

keys on the keypad of the Intelligent Interface Device, or from a remote
terminal. The numbers contained in this guide will act as a quick reference to
accessing menu functions. Single-digit numbers relate to specific main
menus. Double-digit numbers relate to specific sub-menus.

Remote Terminal Quick Reference

iv

1

SYSTEM PARAMETERS

EFFICIENCY
BATTERY TEMPERATURE

11

START TEST

12

STOP TEST

2

INPUT PARAMETERS

VOLTAGE
CURRENT
VOLT AMPS
POWER IN WATTS
POWER FACTOR
LINE FREQUENCY

3

OUTPUT PARAMETERS

VOLTAGE
CURRENT
VOLT AMPS
POWER IN WATTS
POWER FACTOR
LINE FREQUENCY

4

BATTERY PARAMETERS
41

VOLTAGE

42

CHARGER CURRENT

43

CHARGER STATUS

5

USER PARAMETERS
51

SET TIME

52

SET DATE
SET TEST SCHEDULE

53

SET TEST START TIME

54

SET TEST START DATE

55

SET TEST FREQUENCY

56

SET TEST DURATION

57

BATTERY AH CAPACITY

58

SET USER / HISTORY SECURITY CODE

59

SET MAINTENANCE SECURITY CODE

IID SOFTWARE VER.

CFR SOFTWARE VER.

MICROBD SER. NO.

EEPROM VERSION NO.

POWERBD SER. NO.

IID SERIAL NO.

501

SET MODEM PHONE NUMBER (ATDT18003225742)

502

SET PAGER ID STRING (7589210)

503

SET MODEM MESSAGE STRING

6

HISTORY LOGS
61

DISPLAY EVENT HISTORY

62

CLEAR EVENT HISTORY

7

MAINTENANCE PARAMETERS

71

FAST DETECT HI REF

72

MEDIUM DETECT LO REF

73

MEDIUM DETECT HI REF

74

SLOW DETECT LO REF

75

SLOW DETECT HI REF

76

SLOW DETECT HYS LO REF

77

SLOW DETECT HYS HI REF

78

MAX. PLL SLEW RATE

79

BATTERY WARNING REF.