8” aflp low profile, Aflp 2/26trt 8ar, Aflp 2/32trt 8ar – Gotham 8 AFLP Low Profile SpecSheet User Manual
Page 3: Aflp 2/42trt 8ar
© 2010-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 10/07/13. Specifications subject to change without notice.
PAGE 3 OF 3
AFLP-8-OPEn
PH
OTO
M
ET
RY
Distribution Curve
Distribution Data
Output Data
Coefficient of Utilization
Illuminance: Single Luminaire 30” Above Floor
8” AFLP
Low Profile
Horizontal DTT or TRT lamp
PHOTOMETRY NOTES
•
Tested to current IES and NEMA standards under stabilized laboratory conditions.
•
Actual performance may differ as a result of end-user environment and application.
•
Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
AFLP 2/26TRT 8AR
(2) CF26TRT, 1800 LUMENS PER LAMP, 1.3 S/MH, TEST NO. LTL18913
AFLP 2/32TRT 8AR
(2) CF32TRT, 2400 LUMENS PER LAMP, 1.2 S/MH, TEST NO. LTL18912
AFLP 2/42TRT 8AR
(2) CF42TRT, 3200 LUMENS PER LAMP, 1.2 S/MH, TEST NO. LTL18911
0°
20°
40°
60°
80°
400
800
Ave
Lumens
0
5
15
25
35
45
55
65
75
85
90
1008
994
1139
1016
704
433
242
91
2
1
1
98
319
467
447
336
218
90
5
1
Zone
Lumens % Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
884.0
1330.9
1884.3
1980.5
0.0
1980.5
24.6
37.0
52.3
55.0
0.0
*55.0
*Efficiency
%
0
2
f
p
pc
80%
70%
50%
pw
50% 30% 10%
50% 30% 10%
50% 30% 10%
0
1
2
3
4
5
6
7
8
9
10
65
60
54
49
44
40
37
34
31
29
27
65
58
51
45
40
36
33
30
27
25
23
65
56
49
43
37
33
30
27
25
22
21
64
58
53
48
44
40
37
34
31
29
27
64
57
50
45
40
36
33
30
27
25
23
64
56
48
42
37
33
30
27
24
22
21
61
56
51
46
42
39
36
33
30
28
26
61
55
49
44
39
35
32
29
27
25
23
61
54
47
41
37
33
30
27
24
22
20
RCR
50% beam -
64.7°
10% beam -
98.0°
Mounting
Height
Inital FC
Center
Beam Diameter FC Diameter FC
8.0
10.0
12.0
14.0
16.0
33.3
17.9
11.2
7.6
5.5
7.0
9.5
12.0
14.6
17.1
16.7
9.0
5.6
3.8
2.8
12.7
17.3
21.9
26.5
31.1
3.3
1.8
1.1
0.8
0.6
0°
20°
40°
60°
80°
600
1200
Ave
Lumens
0
5
15
25
35
45
55
65
75
85
90
1447
1432
1591
1388
955
581
314
119
1
1
0
139
444
638
604
450
283
116
6
1
Zone
Lumens % Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
1221.2
1825.2
2558.3
2681.1
0.0
2681.1
25.4
38.0
53.3
55.9
0.0
*55.9
*Efficiency
%
0
2
f
p
pc
80%
70%
50%
pw
50% 30% 10%
50% 30% 10%
50% 30% 10%
0
1
2
3
4
5
6
7
8
9
10
66
61
55
50
45
41
38
35
32
30
28
66
59
52
46
41
37
34
31
28
26
24
66
57
50
43
38
34
31
28
25
23
21
65
59
54
49
45
41
37
34
32
29
27
65
58
51
46
41
37
33
30
28
26
24
65
56
49
43
38
34
31
28
25
23
21
62
57
52
47
43
40
36
34
31
29
27
62
56
50
45
40
36
33
30
28
25
23
62
55
48
42
38
34
30
27
25
23
21
RCR
50% beam -
62.9°
10% beam -
96.7°
Mounting
Height
Inital FC
Center
Beam Diameter FC Diameter FC
8.0
10.0
12.0
14.0
16.0
47.8
25.7
16.0
10.9
7.9
6.7
9.2
11.6
14.1
16.5
23.9
12.9
8.0
5.5
4.0
12.4
16.9
21.4
25.8
30.3
4.8
2.6
1.6
1.1
0.8
0°
20°
40°
60°
80°
800
1600
Ave
Lumens
0
5
15
25
35
45
55
65
75
85
90
1787
1804
2016
1788
1225
736
389
144
1
0
0
175
563
819
773
571
352
140
7
0
Zone
Lumens % Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
1556.7
2329.5
3251.9
3399.0
0.0
3399.0
24.3
36.4
50.8
53.1
0.0
*53.1
*Efficiency
%
0
2
f
p
pc
80%
70%
50%
pw
50% 30% 10%
50% 30% 10%
50% 30% 10%
0
1
2
3
4
5
6
7
8
9
10
63
58
52
47
43
39
36
33
31
28
26
63
56
50
44
39
35
32
29
27
25
23
63
55
47
41
37
33
29
26
24
22
20
62
57
51
47
42
39
36
33
30
28
26
62
55
49
44
39
35
32
29
27
24
23
62
54
47
41
36
32
29
26
24
22
20
59
54
50
45
41
38
35
32
30
28
26
59
53
47
43
38
35
31
29
26
24
22
59
52
46
40
36
32
29
26
24
22
20
RCR
50% beam -
63.8°
10% beam -
97.0°
Mounting
Height
Inital FC
Center
Beam Diameter FC Diameter FC
8.0
10.0
12.0
14.0
16.0
59.1
31.8
19.8
13.5
9.8
6.8
9.3
11.8
14.3
16.8
29.5
15.9
9.9
6.8
4.9
12.4
16.9
21.5
26.0
30.5
5.9
3.2
2.0
1.4
1.0