RS-232 Programming • Appendix A

Extron • System 5cr Switcher • User’s Manual

Advanced Instructions – Reserved for Windows program

IR Block

ASCII

Hex

Unit response

Read (Upload)

n/a

80 83

8k bytes of data

Write (Download)

n/a

80 82 [8k bytes]

Dnl

¿

Flag Block

ASCII

Hex

Unit response

Read (Upload)

n/a

80 85

15 bytes of data

Write (Download)

n/a

[Byte0]*[Byte1]91

Dnl

¿

n/a

[Byte2]*[Byte3]93

Dnl

¿

n/a

[Byte6]*[Byte7]97

Dnl

¿

n/a

[Byte8]* 30 99

Dnl

¿

Unit Reset

ASCII

Hex

Unit response

Reset Unit

n/a

80 81

Upd

¿

Flag Block: Consists of fifteen bytes (0-14) that will used for handling special functions for current and future operation.

Byte 0 – Power on delay
Byte 1 – Power off delay
Byte 2 – Triple action switching delay (.5 second * value)
Byte 3 – Relay control
Byte 4 – n/u
Byte 5 – n/u
Byte 6 – n/u
Byte 7 – Mute control & misc. flags

(msb)

Bit 7 - True = Mute audio upon display-power down.
Bit 6 - True = Limit System volume upon switcher power up.
Bit 5 - True = Send responses to RS-232 commands.
Bit 4 - True = Send channel IR command upon display-power up.
Bit 3 - True = Enable front panel volume
Bit 2 - reserved
Bit 1 - reserved

(lsb)

Bit 0 - reserved
Note: Factory default = all bits on (hex FF).

Byte 8 – Video type (composite video or S-video)
Byte 14 - Checksum