RS-232 Programming • Appendix A
Extron • System 5cr Switcher • User’s Manual
Advanced Instructions – Reserved for Windows program
IR Block
ASCII
Hex
Unit response
Read (Upload)
n/a
80 83
8k bytes of data
Write (Download)
n/a
80 82 [8k bytes]
Dnl
¿
Flag Block
ASCII
Hex
Unit response
Read (Upload)
n/a
80 85
15 bytes of data
Write (Download)
n/a
[Byte0]*[Byte1]91
Dnl
¿
n/a
[Byte2]*[Byte3]93
Dnl
¿
n/a
[Byte6]*[Byte7]97
Dnl
¿
n/a
[Byte8]* 30 99
Dnl
¿
Unit Reset
ASCII
Hex
Unit response
Reset Unit
n/a
80 81
Upd
¿
Flag Block: Consists of fifteen bytes (0-14) that will used for handling special functions for current and future operation.
Byte 0 – Power on delay
Byte 1 – Power off delay
Byte 2 – Triple action switching delay (.5 second * value)
Byte 3 – Relay control
Byte 4 – n/u
Byte 5 – n/u
Byte 6 – n/u
Byte 7 – Mute control & misc. flags
(msb)
Bit 7 - True = Mute audio upon display-power down.
Bit 6 - True = Limit System volume upon switcher power up.
Bit 5 - True = Send responses to RS-232 commands.
Bit 4 - True = Send channel IR command upon display-power up.
Bit 3 - True = Enable front panel volume
Bit 2 - reserved
Bit 1 - reserved
(lsb)
Bit 0 - reserved
Note: Factory default = all bits on (hex FF).
Byte 8 – Video type (composite video or S-video)
Byte 14 - Checksum