beautypg.com

Control inputs/outputs – Extron Electronics VN-QUANTUM User Guide User Manual

Page 95

background image

VN-QUANTUM User Guide

Section 5: Technical Data

I455GB issue 8

Page 95

Control Inputs/Outputs


The following control input/output connectors appear on the ES3301-2 and ES3302 / 3304 Card
Frames.

CONTROL Port

Function: Connection to a VN-COMMANDER control PC.

Connector Type: Shielded RJ-45 Socket.

Pin-out Details:

Pin

Function

Pin

Function

1

TX_D1+ (TX+ )

5

BI_D3–

2

TX_D1– (TX– )

6

RX_D2– (RX– )

3

RX_D2+ (RX+)

7

BI_D4+

4

BI_D3+

8

BI_D4–


Mating Connector: Shielded RJ-45 Plug.

Recommended Cable: Shielded twisted pair (STP).

Max. Cable Length: 100 metres (330 feet).

Comms Standard: 10/100BASE-T (Fast Ethernet)

Default IP Address: Factory-set to 172.28.232.11. No DHCP option.

User-definable via control software.

MEDIA I & II Ports (Not supported on the ES3304 VN-QUNATUM CONNECT)

Function: Connection to a local or wide area network for access to network

content or VN-GLIMPSE sources.

Connector Type: Shielded RJ-45 Socket.

Pin-out Details:

Pin

Function

Pin

Function

1

BI_DA+

5

BI_DC-

2

BI_DA-

6

BI_DB-

3

BI_DB+

7

BI_DD+

4

BI_DC+

8

BI_DD-


Mating Connector: Shielded RJ-45 Plug.

Recommended Cable: Shielded twisted pair (STP).

Max. Cable Length: 100 metres (330 feet).

Comms Standard: 1000BASE-T (Gigabit Ethernet)

Default IP Address: Factory-set to DHCP operation.

Fixed IP address user-definable via control software.