Control inputs/outputs – Extron Electronics VN-QUANTUM User Guide User Manual
Page 95

VN-QUANTUM User Guide
Section 5: Technical Data
I455GB issue 8
Page 95
Control Inputs/Outputs
The following control input/output connectors appear on the ES3301-2 and ES3302 / 3304 Card
Frames.
CONTROL Port
Function: Connection to a VN-COMMANDER control PC.
Connector Type: Shielded RJ-45 Socket.
Pin-out Details:
Pin
Function
Pin
Function
1
TX_D1+ (TX+ )
5
BI_D3–
2
TX_D1– (TX– )
6
RX_D2– (RX– )
3
RX_D2+ (RX+)
7
BI_D4+
4
BI_D3+
8
BI_D4–
Mating Connector: Shielded RJ-45 Plug.
Recommended Cable: Shielded twisted pair (STP).
Max. Cable Length: 100 metres (330 feet).
Comms Standard: 10/100BASE-T (Fast Ethernet)
Default IP Address: Factory-set to 172.28.232.11. No DHCP option.
User-definable via control software.
MEDIA I & II Ports (Not supported on the ES3304 VN-QUNATUM CONNECT)
Function: Connection to a local or wide area network for access to network
content or VN-GLIMPSE sources.
Connector Type: Shielded RJ-45 Socket.
Pin-out Details:
Pin
Function
Pin
Function
1
BI_DA+
5
BI_DC-
2
BI_DA-
6
BI_DB-
3
BI_DB+
7
BI_DD+
4
BI_DC+
8
BI_DD-
Mating Connector: Shielded RJ-45 Plug.
Recommended Cable: Shielded twisted pair (STP).
Max. Cable Length: 100 metres (330 feet).
Comms Standard: 1000BASE-T (Gigabit Ethernet)
Default IP Address: Factory-set to DHCP operation.
Fixed IP address user-definable via control software.