beautypg.com

Tree configuration, Tree configuration example, Installation and operation, cont’d – Extron Electronics VSW 2VGA A User Guide User Manual

Page 28

background image

VSW 2VGA A • Installation and Operation

Installation and Operation, cont’d

2-18

Tree configuration

In a tree configuration, the output of each VSW 2VGA A

switcher is connected to input 1 or input 2 of the next switcher.

This repetition of one switcher's output to another switcher's

input can be repeated for up to a maximum of 10 switchers in

a daisy chain. The output of the last switcher is connected to a

display.
Source signals are connected to input 1 and input 2 of each VSW

2VGA A switcher at the top of the tree through a VSW I AAP

interface. Select the source by pressing the VSW I AAP's Show

Me button for the corresponding switcher.
• Switchers can be daisy chained in this configuration up to

ten levels deep without any signal degradation.

• A power supply is required for each switcher in the

chain that has its output connected to input 1 of the next

switcher.

• Sources can only be selected and connected to the

switcher through the VSW I AAP interface.

• Each VSW I AAP must be configured for the tree

configuration. See

"Using the VSW I AAP"

in this chapter

for additional information.

Tree configuration example

The following illustration is a simple example of daisy chaining

using a tree configuration.