beautypg.com

Power connection, Power connection -13 – Extron Electronics VSW 2VGA A User Guide User Manual

Page 23

background image

VSW 2VGA A • Installation and Operation

2-13

Power connection

One power supply can power up to five daisy chained

switchers. Additional switchers require one or more power

supplies. See

"Daisy chain configuration"

, later in this chapter.

Figure 2-12 shows how to wire the power connector.

Power Supply

Output Cord

Captive Screw

Connector

SECTION A–A

Ridges

Smooth

A

A

3/16” (5 mm) Max.

(to ground)

Figure 2-12 — Power connector wiring

C

The two power cord wires must be kept separate

while the power supply is plugged in. Remove

power before wiring.

C

When you are connecting the power supply, voltage

polarity is critical. Applying power with incorrect

voltage polarity could damage the power supply

and the VSW 2VGA A. Identify the power cord

negative (ground) lead by the ridges on the side of

the cord or a black heat shrink wrapping around it.

N

Strip the jacket to expose 3/16

inch (5 mm) of the

conductors. Do not tin the stripped power supply leads

before installing the captive screw connector. Tinned wires

are not as secure in the captive screw connectors and could

be pulled out.

To verify the polarity before connection, check the no load

power supply output with a voltmeter.

N

The maximum number of switchers that can be daisy

chained is limited by several factors: power consumption,

cable lengths, and the overall distortion of the video and

audio signals.