Connections, Input power — using the iec power cord, Ps 124, cont’d – Extron Electronics PS 124 User Manual
Page 10

PS 124 12 VDC, 4 Amp Power Supply • Installation Manual
PS 124, cont’d
4
Connections
Input power — using the IEC power cord
Use the included IEC power cord to connect the PS 124 to a
100 VAC to 240 VAC, 50-60 Hz power source.
W
The circuit breaker used for this connection should
be rated 20 amps maximum.
Input power — using the Flexible Conduit Adapter
Kit
The optional Flexible Conduit Adapter Kit, part # 70-228-02,
provides a convenient means to replace the IEC power cord with
conduit when required by local codes.
The kit consists of:
• One EMT adaptor plate
• One 6-foot long electrical conduit
• Three 7.5 feet, 18-gauge spade connector power wires
• One UL Listed zip tie wrap
• Three auxiliary crimp style spade connectors designed for
14- to 16-gauge wires
N
Extron recommends using a crimp tool such as Molex
part #19285-0008 to terminate the spade connectors.
Make certain the PS 124 and all connected devices are turned off
and disconnected from the power source before beginning.
W
The circuit breaker used for this connection should
be rated 20 amps maximum.
W
For permanently connected equipment there
must be a readily accessible disconnect device
incorporated in the building installation wiring.
W
Installation and service must be performed by a
qualified electrician only.