Mlc 52 series quick start guide, cont’d, Step 3 – Extron Electronics MLC 52 Series Quick Start Guide User Manual
Page 6
MLC 52 Series Quick Start Guide, cont’d
MLC 52 Series • Quick Start Guide
4
Step 3
Attach cables to the control connector on the MLC 52 rear panel
.
The ports in this connector, from left to right, perform the following functions:
F (Tx) —
Transmits the RS-232 signal for projector control.
This port is present on all models, but it is active only on the RS models.
E (IR OUT) —
Used for connecting an IR Emitter to issue IR commands. Up to two
emitters can be wired to this port. There is a maximum of 100' wiring
distance from the port to the emitter.
D (GND) —
Ground for IR and/or RS-232 projector control
C (IR IN) —
Used for connecting an optional IR Link or IRL 20, so that the IR 452
remote can control the MLC.
B (GND) —
Ground for the +12 VDC power
A (+12V) —
Power input for the product (12 VDC)
IR in
12V DC in
F E D C B A
RS-232 Tx (RS Models Only)
IR out
Control connector pinout
a
.
Wire the control IR port
, if you are going to control the projector via IR. You
can connect Extron IR Emitters or an IR Broadcaster to the IR Out port to
control the display and/or input devices via infrared commands from the
MLC. Up to two IR Emitters can be connected via this connector at one time.
Wire the connector as shown in the following illustration.
MLC 52
control
connector
For the IR Emitter only
IR
Emitter
White striped wire only
IR
Modulated IR
Ground
100 feet (30.5 m) maximum
Place the head of each IR Emitter
over or directly adjacent to the
controlled device’s IR receiver.
Connect up to 2
IR Emitters max.
(#70-283-01).
D
E
F E D C B A
Wiring for IR control