Mp 101, cont’d remote control, Remote connector wiring, Remote control options – Extron Electronics MP 101 Series User Guide User Manual
Page 18: All nominal levels are at ±10

2-10
MP 101 Series • MP 101
MP 101, cont’d
Remote Control
The wiring and control options described below pertain to all
models in the MP 101 series.
Remote connector wiring
As shown below, Pin 1 is 10 VDC reference voltage. Pin 2 is
volume control DC voltage; range is 0 to 10 V, where 0 V is mute
and 10 V provides maximum volume. Pin 3 is ground.
N
All nominal levels are at ±10%.
REMOTE
10V
VOL/MUTE
1
2
3
GND
10K
2K
MAX
2
3
1
MIN
POWER
12V
0.5A MAX
MIC
INPUT
REMOTE
VOL/MUTE
MP 101
MIC TO LINE
PREAMPLIFIER
10V
LINE
OUTPUT
MUTE
Remote control options
The MP 101 has three remote control options:
1.
The Extron VCM 100 volume/mute controller and
VC 50
volume controller use a 10 k ohm potentiometer as
the main method for controlling volume levels.
The VCM 100 includes an illuminated Mute button and
operates in sync with the MP 101 AAP.
2.
The Extron MLA-VC10 converts RS-232 serial command
to 0~10 volt variable DC for volume control.
3.
Generic volume/mute controllers are standard 10 k ohm
potentiometers.