beautypg.com

Extron Electronics IPL T CR48 User Manual

Page 36

background image

Command/r

esponse table for SIS commands (continued)

Command

ASCII (T

elnet)

URL Encoded (W

eb)

Response

Clear user passwor

d

24

E

CU

}

W

%20

CU

|

Ipu

]

Read user passwor

d

24

E

CU

}

WCU

|

X3#]

Set verbose mode

24

E

X2@

CV

}

W

X2@

CV

|

Vrb

X2@]

Read verbose mode

E

CV

}

WCV

|

X2@]

Read connection security level

E

CK

}

WCK

|

X5@]

Configur

e br

oadcast mode

E

X6$

EB

}

W

X6$

EB

|

Bmd

X6$]

V

iew br

oadcast mode

E

EB

}

WEB

|

X6$]

Get connection count

E

CC

}

WCC

|

Number of Connections

]

File Commands

Str

eam files via port 80

Load file to user flash memory

Use a POST on port 80, followed by the delimited data to be written to the flash file memory

Retrieve file fr

om user flash

memory

Send a page GET on port 80 followed by WSF

|

{The r

esponse is raw data fr

om the file}

Example:

http://192.168.254.254/mypage.html?cmd=WSF

|

{data fr

om the file

mypage.html

}

Str

eam files via T

elnet

Load file to user flash memory

24 28

E

+UF

, filesize

, filename

}

{raw unpr

ocessed data fr

om the file up to filesize}

Upl

]

Retrieve file fr

om user flash

memory

24 28

E

filename

SF

}

1B

filename

53

46

0D

{4 bytes of

filesize

, and then raw data

fr

om the file}

Re-map Port Designations

Set T

elnet port map

24

E

port#

MT

}

W

port#

MT

|

Pmt

port#

]

Reset T

elnet port map

24

E

23MT

}

W23MT

|

Pmt00023

]

Disable T

elnet port map

24

E

0MT

}

W0MT

|

Pmt00000

]

Read T

elnet port map

24

E

MT

}

WMT

|

port#

]

Set W

eb port map

24

E

port#

MH

}

W

port#

MH

|

Pmh

port#

]

NOTE:

Duplicate port number assignments ar

e not permitted (T

elnet and W

eb cannot be the same) and will r

esult in an E13 (invalid parameter) err

or

.

Remapping of the port number (other than to “Reset” to default assignment of 80/23 or “Disable” by setting to 0) must be to ports 1024 or higher

.

NOTE:

X2@

=

Verbose/r

esponse mode status: 0 = clear

, default for T

elnet connections; 1 = verbose mode is on; 2 = send tagged r

esponses for queries;

3 = verbose mode is on and tagged r

esponses ar

e sent for queries

X3#

= Passwor

d: maximum length of 12 characters and no special characters

X5@

= Connection security level: 0 = not logged in; 11 = user; 12 = administrator

X6$

= Br

oadcast r

epetition rate in seconds (0-255. 0 = disable)

IPL T CR48 • Communication and Control

30