X3*
= Event data size: bit; Byte (8-bit); Short (16-bit); Long (32-bit) (only first letter is required)
NOTE:
This parameter is case-sensitive.
X3(
= Event data to write
X4#
= 0 = off; 1 = on; value = 0-4095, based on 12-bit A to D
X4$
= Number of bytes to read
X4%
= E-mail event number: range = 1-64 max
X4^
= E-mail recipient address: maximum number of characters for full e-mail address is 31 characters.
X4&
= Name of e-mail file to be sent: the first line of the file is the subject, the rest is the body of the e-mail.
NOTE:
E-mail files must have the *.eml extension.
X4(
= Default name: Combination of model name and last 3 pairs of MAC address (for example,
IPL-T-CR48-00-02-3D)
X5!
= Direct access: 0 = Direct access not in use; 1 = direct access in use
X5@
= Connection security level: 0 = not logged in; 11 = user; 12 = administrator
X5#
= Timeout for data pass-through mode, after which event data can be inserted into the transmit buffer
X5$
= ASCII digits representing numeric value of data element read from event buffer (leading zeros are
suppressed)
X6#
= Pulse time in 20 milliseconds per count. If parameter is missing or = 0, pulse length = default
(25 counts = 500 milliseconds), max (65536 counts)
X6$
= Broadcast repetition rate in seconds (0 - 255, default = 0)
NOTE:
Zero (0) clears broadcast mode.
Copyright information
]
(c) COPYRIGHT 2009, EXTRON ELECTRONICS IPL T CR48, V
x.xx, 60-544-x5
]
Tue, 10 Aug 2010 16:29:10
]
The copyright message is displayed upon connecting to the IP Link
®
product via TCP/IP or
Telnet. V
x.xx is the firmware version number. The part number of the unit, the current
date, and time are displayed as well. This is followed by a password prompt.
Password information
The “
]
Password:” prompt requires a password (administrator level or user level) followed
by a carriage return. The prompt is repeated if the correct password is not entered.
If the correct password is entered, the unit responds with “
]
Login Administrator
]
” or
“
]
Login User
]
” depending on the password entered. If passwords are the same for both
administrator and user, the unit defaults to administrator privileges.
IPL T CR48 • Communication and Control
25