beautypg.com

Extron Electronics IPL T CR48 User Manual

Page 31

background image

X3*

= Event data size: bit; Byte (8-bit); Short (16-bit); Long (32-bit) (only first letter is required)

NOTE:

This parameter is case-sensitive.

X3(

= Event data to write

X4#

= 0 = off; 1 = on; value = 0-4095, based on 12-bit A to D

X4$

= Number of bytes to read

X4%

= E-mail event number: range = 1-64 max

X4^

= E-mail recipient address: maximum number of characters for full e-mail address is 31 characters.

X4&

= Name of e-mail file to be sent: the first line of the file is the subject, the rest is the body of the e-mail.

NOTE:

E-mail files must have the *.eml extension.

X4(

= Default name: Combination of model name and last 3 pairs of MAC address (for example,

IPL-T-CR48-00-02-3D)

X5!

= Direct access: 0 = Direct access not in use; 1 = direct access in use

X5@

= Connection security level: 0 = not logged in; 11 = user; 12 = administrator

X5#

= Timeout for data pass-through mode, after which event data can be inserted into the transmit buffer

X5$

= ASCII digits representing numeric value of data element read from event buffer (leading zeros are

suppressed)

X6#

= Pulse time in 20 milliseconds per count. If parameter is missing or = 0, pulse length = default

(25 counts = 500 milliseconds), max (65536 counts)

X6$

= Broadcast repetition rate in seconds (0 - 255, default = 0)

NOTE:

Zero (0) clears broadcast mode.

Copyright information

]

(c) COPYRIGHT 2009, EXTRON ELECTRONICS IPL T CR48, V

x.xx, 60-544-x5

]

Tue, 10 Aug 2010 16:29:10

]

The copyright message is displayed upon connecting to the IP Link

®

product via TCP/IP or

Telnet. V

x.xx is the firmware version number. The part number of the unit, the current

date, and time are displayed as well. This is followed by a password prompt.

Password information

The “

]

Password:” prompt requires a password (administrator level or user level) followed

by a carriage return. The prompt is repeated if the correct password is not entered.

If the correct password is entered, the unit responds with “

]

Login Administrator

]

” or

]

Login User

]

” depending on the password entered. If passwords are the same for both

administrator and user, the unit defaults to administrator privileges.

IPL T CR48 • Communication and Control