DTP T HWP/UWP 232/332 D Transmitters • Installation and Operation

14

RS-232 and IR Connector Wiring

Remote RS-232 and Contact Closure Connector

Wire the rear Remote RS-232 and contact closure connector as shown in figure 11.

Ground

Receive pin on connected unit

Transmit pin on connected unit

Connected RS-232 and

Contact Closure Device Pins

Tx/Rx

Pins

Pin 1 for contact closure control

Pin 2 for contact closure control

Rx

Tx

RS-232

Contact

2

1

G

REMOT

E

Figure 11.

RS-232 and Contact Closure Connector Wiring

IR Control Connector

Wire the front panel IR control connector as shown in figure 12.

G

Ground

S

Signal

Figure 12.

IR Out Connector Wiring

Over DTP RS-232 Connector

Wire the rear Over DTP RS-232 connector as shown in figure 13.

Tx Rx

G

OVER DTP

Ground

Receive pin on connected unit

Transmit pin on connected unit

Figure 13.

Over DTP Connector Wiring

NOTE: Do not tin the wires before installing them in the direct insertion connector.

Tinned wires are not as secure in the connectors and could be pulled out.