Remote control, Simple instruction set control, Host-to-unit instructions – Extron Electronics FOXBOX SR HDMI User Guide User Manual
Page 26

Remote Control
This section describes the remote control operation of the FOXBOX SR HDMI, including:
•
Simple Instruction Set Control
•
Signal Processing Product Control Program
The receiver has two serial ports: the front panel Configuration port, a 2.5 mm mini stereo
jack (see “
Front panel Configuration Port
“ on page 11); and a rear panel Remote
RS-232 port, a 3-pole captive screw connector (see “
“ on page 8).
Either of these ports can be connected to a host device such as a computer running the
HyperTerminal or DataViewer utility, or a control system to make serial control of the
receiver possible.
The protocol for all ports is as follows:
•
9600 baud
•
no parity
•
8 data bits
•
1 stop bit
•
no flow control
Simple Instruction Set Control
Host-to-Unit Instructions
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command character sequence. When a command is valid, the
unit executes the command and sends a response to the host device. All responses from
the unit to the host end with a carriage return and a line feed (CR/LF = ]), which signals
the end of the response character string. A string is one or more characters.
FOXBOX SR HDMI • Remote Control
20