Installation, cont’d

Digital Display Scaler • Installation

2-4

5

RGB/HD R-Y, B-Y, Y Output BNC connectors —

Connect an RGB video or

HD component video display to these female BNC connectors (figure 2-4).

V

H

RGBHV video

RGBS video

Component video (R-Y, B-Y, Y)

S

S

H

V

R

/R-Y

G

/Y

B

/B-Y

R

/R-Y

G

/Y

B

/B-Y

V

H

S

R

/R-Y

G

/Y

B

/B-Y

Figure 2-4 — BNC output connections for RGBHV, RGBS, and component
video

For RGBHV video —

Connect to five BNC connectors.

For RGBS video —

Connect to four BNC connectors.

For component video —

Connect to three BNC connectors.

RS-232 connection

6

Remote port —

Connect a host device, such as a computer or touch panel

control, to the Digital Display Scaler via this 9-pin D connector for serial
RS-232 control (figure 2-5).

Female

5

1

9

6

Male

1

5

6

9

RS-232 Function

Pin

1
2
3
4
5
6
7
8
9

TX
RX

Gnd




Contact closure, input #1
Transmit data
Receive data
Contact closure, input # 2
Signal ground
Not used
Not used
Not used
Not used

Figure 2-5 — Remote port pin assignments

See chapter 4, Programmer’s Guide, for definitions of the SIS commands and
chapter 5, Scaler Software to install and use the control software.

Contact closure connection

6

Remote port —

The Remote connector also provides a way to select an input

using a remote contact closure device. Contact closure control uses pins on
the Remote connector that are not used by the RS-232 interface (figure 2-5).

To select a different input number using a contact closure device, momentarily
short the pin for the desired input number to logic ground (pin 5). To force
one of the inputs to be always selected, leave the short to logic ground in
place. The short overrides front panel input selections.

Power connection

7

AC power connector —

Plug a standard IEC power cord into this connector

to connect the scaler to a 100 to 240VAC, 50 Hz or 60 Hz power source. The
front panel control and input selection buttons light in sequence during
power-up, the LCD displays the product name and then cycles through the
default messages.

Configuration

DDS 402 can be configured using either the front panel controls, the SIS, or the
Windows Control program. See chapter 3, Operation, chapter 4, Programmer’s Guide,
and chapter 5, Scaler Software for more information.