beautypg.com

Xylem FOM 320 User Manual

Page 4

background image

4

Deutsch

FOM 320










































Inhaltsverzeichnis

Sicherheitshinweise .......................... 8

1 Beschreibung ............................... 10

2 Lieferumfang................................. 12

3 Bedienung ..................................... 12

3.1 Einschalten des FOM 320

.............. 12

3.2 Speicherplatz auswählen

............... 14

3.3 Short-Cut

.......................................... 16

3.4 Durchführen einer Messung mit dem
FOM 320

................................................. 18

3.5 Reinigung

......................................... 22

4 User Menü ..................................... 24

4.1 Aufruf des User Menü

..................... 24

4.2 Übersicht des User Menüs

............. 24

4.3 Einstellmöglichkeiten

...................... 26

4.3.1 Aktivieren einer Speicherstelle:
SET ..................................................... 28
4.3.2 Auswahl einer Fettklasse: FATCL
........................................................... 28
4.3.3 Einstellung der Startwerte der
Ölklassen zur Justierung: FR PC......... 28
4.3.4 Offset-Korrektur: OFSET ............ 30
4.3.5 Steigungskorrektur: GAIN ........... 32
4.3.6 Grenzwert für LED grün: LIM 1 ... 32
4.3.7 Grenzwert für LED rot: LIM 2 ...... 34
4.3.8 Löschen der Speicherwerte: CLR 34
4.3.9 Temperatureinheit: UNIT ............ 36
4.3.10 Auto hold: AHOLD .................... 36
4.3.11 Versionsstand: INFO ................ 36
4.3.12 Beenden der Einstellungen: EXIT
........................................................... 38

4.4 Anwender Justierung ........................... 40

4.5 Justierung löschen............................... 42

Manual FOM 320

53

Francais

English

II Technical data

Measuring oil quality

Measurementrange .... 0 to40 % polar
compounds
Accuracy (typical) ......................... ±2 % PC
Resolution .................................. 0.5 % PC
Temperature range ............. +50 to +200 °C
Optimum range ................+150 to +180 °C

Temperature measuring

Accuracy ............................................ ±1 °C
Resolution ........................................ 0,1 °C
Response time t

90

..................................................

<2 min

Instrument

Operating temperature
Instrument housing ............. -10 to +50 °C
Sensor .................................... 0 to +200 °C
Battery ......................... Lithium button cell
............................ 3 V/1 Ah,Type CR 2477
Battery life ........................ typically 5 Jahre
Dimensions
(L x W x H) ..................... 304 x 54 x 22 mm
Housing material .................................ABS
Protection class ................................. IP 67
Maximum altitude ....................................

















II Caractéristiques techniques

Mesure de la qualité d’huile

Plage de mesure: 0 à 40% de composés
polaires
Exactitude (typique) ..................... ±2 % CP
Résolution .................................. 0,5 % CP
Plage de température .......... +50 à +200 °C
Plage optimale .................. +150 à +180 °C

Mesure de la température

Exactitude .......................................... ±1 °C
Résolution ........................................ 0,1 °C
Constante temps t

90

..........................................

<2 min

Instrument de mesure

Température de service
Boîtier de l’instrument ........... -10 à +50 °C
Sonde....................................... 0 à+200 °C
Pile ............................ Pile ronde au lithium
........................... 3 V/1 Ah, Type CR 2477
Durée de vie de la pile ......... environ 5 ans
Dimensions:
(L x l x h) ........................ 304 x 54 x 22 mm
Boîtier ..................................................ABS
Indice de protection ........................... IP 67
Maximale altitude .....................................