beautypg.com

Data sheet, Charge function descriptions (continued) – Diodes AUR9807 User Manual

Page 19

background image


Data Sheet

Single-cell Li-Ion Charger IC with System Power Management AUR9807

Nov. 2011 Rev. 1. 0 BCD Semiconductor Manufacturing Limited

19

Charge Function Descriptions (Continued)


charger function can be disabled by pulling up the
SYSOFF pin; in this mode, the AUR9807 is almost a
regulator to power the system. Because the power path
is cut off, the output voltage will drop to zero when the
input source is removed, the battery will not be used to
power the system. The SYSOFF pin is pulled high
internally; therefore, this pin should be pulled to ground
for normal operation.

Recharge Process and Timer Fault
Elimination

If timeout occurs and the battery voltage is higher
than the recharge threshold, the charger will stay in
the charge done mode until the battery voltage drops
below the recharge threshold. Once the battery
voltage drops below the recharge threshold, a new


charge cycle starts.

If timeout occurs and the battery voltage is lower
than the recharge threshold, the charger will indicate
a fault condition and an internal resistor between
output and battery will try to pull up the battery
voltage. If the internal resistor is unable to pull up the
battery voltage to the recharge threshold, the charger
will stay in fault condition. Once the battery voltage
is higher than the recharge threshold, the charger
removes the pull-up resistor, leaves the fault
condition and stay in the charge done mode
temporarily. The charger then waits the battery
voltage to drop below the recharge threshold and
starts a new charge cycle.