beautypg.com

7 rebuilding the raid, 6 exiting the intel, Matrix storage manager – Asus P7F-E User Manual

Page 128: Rebuilding the raid with other non-raid disk

background image

5-32

Chapter 5: RAID configuration

Select a destination disk with the same size as the original hard disk.

[

DEGRADED VOLUME DETECTED

]

[↑↓]-Previous/Next [ENTER]-Select [ESC]-Exit

"Degraded" volume and disk available for rebuilding detected. Selecting

a disk initiates a rebuild. Rebuild completes in the operating system.

Select the port of destination disk for rebuilding (ESC to exit):

Port Drive Model Serial # Size

X XXXXXXXXXXX XXXXXXXX XX.XGB

5.3.7

Rebuilding the RAID

This option is only for the RAID 1 set.

Rebuilding the RAID with other non-RAID disk

If any of the SATA hard disk drives included in the RAID 1 array failed, the system

displays the status of the RAID volume as “

Degraded” during POST. You can

rebuild the RAID array with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:

1. At the prompt, press + to enter the Intel Matrix Storage Manager

option ROM utility.

2. If there is a non-RAID SATA Hard Disk available, the utility will prompt to

rebuild the RAID. Press , and then use up/down arrow keys to select

the destination disk or press to exit.

5.3.6

Exiting the Intel

®

Matrix Storage Manager

To exit the utility

1. From the utility main menu, select

5. Exit, and then press . The

following warning message appears.

2. Press to exit or press to return to the utility main menu.

Are you sure you want to exit? (Y/N):

[

CONFIRM EXIT

]