The product in operation – OSRAM POWERTRONIC PT-FIT I ECG for HID lamps, with cable clamp User Manual
Page 26
THE PRODUCT IN OPERATION
26
Dimming means reducing wattage to save energy.
The following values emerge per DIM level, lamp type
and wattage for each system.
Light and wattage details for a PTo 50 3DIM system
PTo 50 3DIM
HCI-TT 50W WDL
NAV-T 50W Super
DIM-Level
[%]
PL
[W]
PS
[W]
PHI
[lm]
ETA
[lm/W]
ETA sys
[lm/W]
CT
[K]
Ra
PHI
[lm]
ETA
[lm/W]
ETA sys
[lm/W]
100
50.5
56.4
4960
98.1
87.9
3041
79
4005
79.3
71.0
90
45.7
51.2
4375
95.7
85.5
3183
75
3380
73.9
66.0
80
40.6
45.6
3725
91.8
81.7
3389
71
2715
66.8
59.5
75
37.9
42.7
3375
89.1
79.0
3521
69
2380
62.7
55.7
70
36.0
40.6
3115
86.6
76.7
3634
67
2140
59.4
52.7
60
33.6
38.1
Not released, dimming to 60 %
1890
56.3
49.6
Light and wattage details for a PTo 70 3DIM system
PTo 70 3DIM
HCI-TT 70W WDL
NAV-T 70W Super
DIM-Level
[%]
PL
[W]
PS
[W]
PHI
[lm]
ETA
[lm/W]
ETA sys
[lm/W]
CT
[K]
Ra
PHI
[lm]
ETA
[lm/W]
ETA sys
[lm/W]
100
73.3
80.9
7150
97.5
88.4
3003
89
6810
92.9
84.2
90
64.5
71.4
6280
97.4
88.0
3056
84
5675
88.0
79.5
80
56.6
62.8
5435
96.1
86.5
3141
80
4595
81.2
73.1
75
51.8
57.8
4890
94.4
84.7
3225
78
3940
76.0
68.2
70
47.8
53.4
4430
92.7
82.9
3322
75
3400
71.2
63.7
60
46.1
51.8
4175
90.5
80.6
3439
73
3150
68.3
60.8