OLED INTEGRATION

In this example, elastomeric connectors are used for inter-

connecting OLEDs. Similar low-resistance connectors can

be used accordingly. The product can be acquired from

Nucletron Technologies GmbH, Munich.

The connectors should cover the contact ledges completely to

minimize contact resistance. They have to be compressed by

5 – 25 % of their height to ensure optimal conductivity and

vibration resistance. The carrier of the OLED has to provide a

suffi cient holding force and also has to fi x the connectors late-

rally. To calculate the force needed, consult the datasheet of

the connectors. Keep in mind that the active area of the OLEDs

should not be exposed to mechanical stress.

1.5. Contacting of OLED tiles via elastomeric connectors

Fig. 4. Front side of an ORBEOS

®

CMW-031. The elastomeric connectors (light blue) have to be compressed to ensure suffi cient electrical connection.

F