beautypg.com

Wiring and configuration of the ecg – OSRAM OPTOTRONIC Constant current LED power supplies with 3DIM User Manual

Page 15

background image

15

WIRING AND CONFIGURATION OF THE ECG

The StepDIM parameters (power-on level, dim level
and dim fade time) are preset by OSRAM and stored in
the ECG. Notes on the factory settings can be found in
chapter 3.1.

For exact factory settings, please refer to the datasheet
of the respective ECG.

The factory settings can be modifi ed by the user via the
3DIM Tool. In principle, the power-on level can be set low-
er than the dim level. The minimum dim level, however, is
limited by the ECG.

Note: “Low” signal means the SD port fl oating, neither
neutral nor phase are connected to this port.

Figure 19: StepDIM behavior – “StepDIM/DALI” mode (factory settings).

Figure 20: StepDIM inverse behavior – “StepDIM inverse/DALI” mode.

Table 6: StepDIM operating modes

Operating mode

SD control state

Note

HIGH

LOW

AstroDIM/
StepDIM/DALI
(wiring selection)

Dim level

Power-on level

Figure 19 – factory set-
tings

StepDIM/DALI

Dim level

Power-on level

Figure 19 – setting via
3DIM Tool

StepDIM inverse/DALI

Power-on level

Dim level

Figure 20 – setting via
3DIM Tool

Dim duration

Dim duration

Power-on level

Power-on level

Dim level

Dim level

ON

ON

HIGH

HIGH

OFF

OFF

LOW

LOW

Time (h)

Time (h)

Time (h)

Time (h)

Time (h)

Time (h)

Fade
time

Fade
time

Fade
time

Fade
time

Po

wer (%)

Po

wer (%)

Mains

Mains

SD state

SD state