SENA ProBee-ZU10 User Manual
Page 62

62
ProBee-ZU10 User Guide Rev.1.5
the sleepy end-device to poll more rapidly for a short time when receiving RF data.
Execute
ATS52?
ATS52=
Response
OK
OK
Default
100
Range
0 - 10000
7.4.3
S53
Description
Get/Set the sleep duration in quarter seconds. An end-device sleeps at this time and
turns off radio every sleep cycle. If a node sleeps over poll timeout of parent node, the
device will be removed from the child table.
Execute
ATS53?
ATS53=
Response
OK
OK
Default
8
Range
0 – 16711680
7.4.4
S54
Description
Get/Set the standby timeout in seconds. When an end-device wakes up and polls with
the parent node, the node will wait for another data from the ZigBee network or from
the serial port for S54 before it goes to sleep mode again. If any serial or RF data is
sent or received, the timer will reset and wait for next again.
Execute
ATS54?
ATS54=
Response
OK
OK
Default
5
Range
0 – 10000
7.4.5
S55
Description
Get/Set the rejoin timeout. If it is enabled, an end-device tries to rejoin the current
network when contact with the network has been lost for setting value in seconds. The
most common usage case is when an end-device can no longer communicate with its
parent and wishes to find a new one.
Execute
ATS55?
ATS55=
Response
OK
OK
Default
10
Range
0 – 10000