SENA ProBee-ZU10 User Manual
Page 47

47
ProBee-ZU10 User Guide Rev.1.5
5.7
Data Transmission and Reception
5.7.1
AT+DESTLA or AT+DL
Description
Get/Set the 64-bit destination IEEE address for unicast data transmission.
Execute
AT+DESTLA?
AT+DESTLA=
Response
OK
OK
Default
0000000000000000
Range
0000000000000000 - FFFFFFFFFFFFFFFF
5.7.2
AT+DESTGROUPID or AT+DG
Description
Get/Set the 16-bit destination Group ID for multicast data transmission.
Execute
AT+DESTGROUPID?
AT+ DESTGROUPID=
Response
OK
OK
Default
0000
Range
0000 – FFFF
5.7.3
AT+SINKINFO or AT+SI
Description
Get the long and short addresses of sink node. If there is no sink node in the network,
the addresses will be “FFFFFFFFFFFFFFFF” and “FFFF”.
Execute
AT+SINKINFO?
Response
OK
5.7.4
AT+MAXPAYLOAD or AT+MP
Description
Get the maximum size of the payload that the Application Support sub-layer will
accept. The size depends on the security level in use.
Execute
AT+MAXPAYLOAD?
Response
OK
5.7.5
AT+TRASNSMITMODE or AT+TM
Description
Get/Set the data transmission mode. This mode is maintained after rebooting. (0:
none, 1: unicast to destination long address, 2: multicast to destination group ID, 3:
broadcast to all nodes, 4: unicast to sink node)
Execute
AT+TRANSMITMODE?
AT+TRANSMITMODE=
Response
OK
OK
Default
0