B: Specifications
891-00000-000-02-201401
23
QE Pro Specifications
The following sections provide specification information for the CCD detector in the QE Pro, as well as
the QE Pro Spectrometer itself.
CCD Detector Specifications
Specification
Value
Detector
Hamamatsu S7031-1006 Low Etaloning
Detector range
185-1100 nm
Pixels
1024 active
Pixel size
24 μm
2
Quantum efficiency
90% peak; 65% at 250 nm. See Quantum Efficiency of Detector graph
below.
QE Pro Spectrometer Specifications
Specification
Value
Integration time
8 ms to 60 minutes
Typical dynamic range
~85,000:1
Signal-to-noise ratio
1000:1 (single acquisition)
Readout Noise
2.5 counts RMS (typical)
Stray light
<0.08% at 600 nm; 0.4% at 435 nm
Linearity
Corrected
0.5% nonlinearity (max)
f number
f/4
Fiber optic connector
SMA 905 and Ocean Optics FC
Gratings
14 gratings available (H1--H14),
HC1 grating
Entrance aperture
5, 10, 25, 50, 100 or 200 µm wide slits
(or SMA/FC bulkhead with no
slit)
- Apex 785 Raman (1 page)
- STS-UV (2 pages)
- TR2 Engineering Note (4 pages)
- SAD500 Communications and Control (19 pages)
- Red Tide USB650 Install (26 pages)
- Fiber Optic Termination Kit (6 pages)
- Transmissive pH Probe (10 pages)
- Remora (42 pages)
- PlasCalc (59 pages)
- Correcting Device Driver Issues (8 pages)
- ecoVis Krypton Light Source (16 pages)
- LPC-500CM (28 pages)
- HPX-2000 (24 pages)
- ADC1000-USB (27 pages)
- Torus Operating Instructions (30 pages)
- ADC2000-PCI (13 pages)
- Sensors for Real-Time Analysis (2 pages)
- IDRaman reader (2 pages)
- DH-2000-CAL (30 pages)
- QE65 Pro (32 pages)
- Collimating Lenses (2 pages)
- D1000 (2 pages)
- IDRaman mini (2 pages)
- HR2000CG-UV-NIR (42 pages)
- Cool Red (1 page)
- HL-2000 (20 pages)
- XE-1 Xenon (6 pages)
- USB-ADP Serial Adapters (3 pages)
- CHEM2000 (36 pages)
- Deuterium-Halogen Calibration Light Source (19 pages)
- NeoFox Engineering Note (30 pages)
- QE Pro (2 pages)
- OOIBase32 (140 pages)
- AR-1 Argon (6 pages)
- pH Sensor Patches, Probes and Cuvettes (36 pages)
- SpecLine Offline Spectroscopy (60 pages)
- HL-2000-HP-232 (26 pages)
- External Triggering Options Instructions for Spectrometers with Firmware Version 3.0 and Above (16 pages)
- Breakout Box (10 pages)
- USB-ISS-UV_VIS (4 pages)
- ISS-UV_VIS (6 pages)
- OOIColor (14 pages)
- LS-1 Series (12 pages)
- Apex Install (24 pages)
- DH-2000 (34 pages)