beautypg.com

Peak surge (non-repetitive) on-state current (i, Amps, Surge current duration – full cycles – Littelfuse E1 Sensitive Triacs User Manual

Page 8

background image

Sensitive Triacs

Data Sheets

http://www.littelfuse.com

E1 - 8

©2004 Littelfuse, Inc.

+1 972-580-7777

Thyristor Product Catalog

Figure E1.9 Peak Surge Current versus Surge Current Duration

Figure E1.10 Power Dissipation (Typical) versus RMS On-state Current

(0.8 A and 1 A)

Figure E1.11 Power Dissipation (Typical) versus RMS On-state Current

(4 A, 6 A, and 8 A)

1

2

4

3

6 8 10

20

40

30

60

100

200

400 600 1000

1

2

3

4

6

10

8

20

30

40

60

100

80

150

200

Surge Current Duration – Full Cycles

Peak Surge (Non-Repetitive)

On-State Current (I

TSM

) – Amps

8 A

6 A

0.8 A

SUPPLY FREQUENCY: 60 Hz Sinusoidal
LOAD: Resistive
RMS On-state Current: [I

T(RMS)

]: Maximum

Rated Value at Specified Case Temperature

NOTES:
1) Gate control may be lost during
and immediately following surge
current interval.
2) Overload may not be repeated until
junction temperature has returned
to steady-state rated value.

1 A

4 A

0

0.25

0.50

0.75

1.0

1.25

1.5

0

0.5

1.0

1.5

RMS On-state Current [I

T(RMS)

] – Amps

Average On-state Power Dissipation

[P

D(AV)

] – Watts

CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360˚

1 A

0.8 A

0

.5

1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5

0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

8.0

6 A and 8 A

4 A

RMS On-state Current [I

T(RMS)

] – Amps

Average On-state Power Dissipation

[P

D(AV)

] – Watts

CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360˚